CHAPTER 2: INSTALLATION AND SETUP
HF28 DC RESISTANCE WELDING SYSTEM
2-8
990-372
DC EZ-AIR Weld Head Connection
1.
Adjust the weld head force adjustment knob to produce 5 units of force, as displayed on the
force indicator index.
2.
Connect the weld head firing switch cable connector to the Control firing switch cable
connector.
3.
Connect a normally closed, approved, emergency stop switch across the two leads of the
operator emergency stop switch cable. This switch, when operated (open), will immediately
stop the weld cycle and retract the weld head. See
Appendix B. Electrical and Data
Connections
for circuit details.
4.
Connect a Model FS2L or FS1L Foot Switch to the Control
FOOT SWITCH
connector.