Standard Air Valve Driver Output Connector
The air valve driver output (24VAC) is initiated when Foot Switch Level 1 is initiated. Using the
supplied Configuration plug on Pins 11 – 20 allows the use of the Miyachi Unitek 2-level footswitch
directly. If a PLC or other means of trigger is used, refer to the I/O Signal Interface General Description
on page B-3. The mating connector is an AMP type 206429-1, using cable clamp AMP type 206358-2.
The two male pins used are Amp type 66361-2.
Air Valve Driver 24 VAC Connector
Pin Description
1
24VAC (for solenoid)
2
HEAD_1 (Switched 24V common)
Voltage Sense Input Connector
The voltage leads are connected to the electrode holders to sense weld voltage.
Voltage Sense Input Connector
Pin Description
1
Not Used
2
VOLT_IN
3
VOLT_COM