CHAPTER 5. OPERATING INSTRUCTIONS
HF28 DC RESISTANCE WELDING SYSTEM
5-4
990-372
8.
Press the
COOL
key to enter the amount of time for the cool period after Pulse 1. Use
the numeric keypad to enter the time or use the
arrows. Enter
0.5
milliseconds.
9.
Program Pulse 2 by repeating Steps 3 through 7 above using the keys for Pulse 2, entering the
value
0
in each step.
10.
Press the
HOLD
key to enter the amount of time for the hold period after the weld. Use
the numeric keypad or the
arrows. Enter a time between
0
and
999
milliseconds.
We recommend at least
50
milliseconds as weld strength is formed in the hold time.