ПРИВОД LG-500 | LG-500 DRIVE)
72
ADjUSTMENT
MENU
SETTING
DESCRIPTION
VALUES
DEFAULT
VALUE
P5
F1
The drive force when opening
. When opening
if the drive detects any obstacle, it will lead to
immediate stop of movement
00
,
01
…
99
00
—minimum force
value;
99
—maximum force
value
65.
F2
The drive force when closing.
When closing
if the drive detects any obstacle, it will lead
to immediate stop of movement and the
subsequent full opening
65.
Y
The necessity of adjusting the force and speed as well as performing such adjustments
are to be carried out by qualified personnel (EN 12635) from a specialised company.
A specialist should also check the system for compliance with the safety standard
(EN 12453 inbuilt device type
C
), or other safety device (EN 12453 device type
E
) should
be applied. The settings shall ensure safe and correct operation of the doors in accordance
with the current regulations eliminating damage and false activating.
P6
F1
The speed of door movement when opening
01
,
02
…
99
01
—minimum
speed value;
99
—maximum
speed value
99.
F2
The speed of door movement when closing
99.
P7
F1
Select the operating mode of the photocells
(input ‘
PH1
’). The input is activated when opening
or is activated when closing
CL
—is activated
when closing /
OP
—is activated
when opening
CL.
F3
Function ‘FOOTEST’
. The operation of the
photocells is checked before movement by
short-term disconnection and then reconnection
of the power to the photocells transmitter.
Photocells connection diagram—
fig
. 26
no
—
OFF
/
on
—
ON
no.
F5
Photocells blocking close to the floor level
and the safety sensor (input ‘SE’)
. The setting
specifies the distance from the floor where the
photocells and the safety sensors are ignored
no
—
OFF
/
01
,
02
,
03
…
99
99
—maximum
~ 200 mm
no.
P8
F1
The setting of output SL / LL in signal lamp
mode SL
: continuous or flashing
no
—flashing /
on
—continuous
on.
F2
The delay time of the movement beginning
(time of the preliminary activation of the signal
lamp). During the delay time, the signal lamp (
SL
)
works, it signals the beginning of door movement
by a set number of seconds
00
,
01
…
10
00
—0
sec
,
10
—10
secs
00.
F3
Operating time in the illumination lamp
(
LL
)
mode and the drive illumination after stopping
the door movement
no
/
01
,
02
…
99
no
—after the end
of door movement it
is off (0 sec)
01
—5
secs
;
99
—500
secs
(8 min 20
secs
)
06.
(30 secs)