ПРИВОД LG-500 | LG-500 DRIVE)
61
PREPARATION FOR ASSEMBLY
The drive can not be used with a gate with a built-in wicket if the drive is not locked when the
wicket door is open.
Please, make sure that the door leaf is balanced, i.e. it remains immobile in any position if released.
Please, make sure that the force, required to move the door leaf manually, does not exceed 150 N
(~ 15 kg). Easy movement of the door leaf should be ensured during closing and opening. The ex-
cess of the force is allowed in the beginning of the movement. The force, required to maintain
the door leaf movement during operation, should not exceed the nominal pull force. The force,
required to start the movement of the door leaf, should not exceed half of the maximum pull
force of the drive. The force reserve is required, as unfavourable weather conditions (such as
wind, icing etc.) and wear of the door components may result in the increase of the force due
to the increase of friction in the system.
Evaluate the possible risk degree (impact, compression, jamming, dragging and other dangers).
Please, identify, which additional devices (accessories) are required to prevent possible risks and
compliance with the safety provisions in force.
Please, make sure that the surface on to which the drive system is installed is solid and can
be used as a reliable and rigid support. If this is not the case, take measures to strengthen the
installation places accordingly.
Please, make sure that the installation places for the drive system components are protected
from impacts. The components must be installed at a safe distance from moving parts.
Please, make sure that foreign objects, water and other liquids are not present inside the drive
and on other open parts, otherwise disconnect the drive from the mains supply and consult the
service centre. The operation of the equipment in such conditions is not safe.
Please, make sure that the drive and its components are at a sufficient distance from heat sources
and open fire. The violation of this requirement can result in the damage of the product, cause
it to malfunctioning, cause fire or create other dangerous situations.
Please, make sure that an easy and safe way of the drive rail manual release is ensured.
The control devices should be located within sight of the door, at a height not less than 1.5 m.
If there is no alternative means of access to the garage or wicket door within the door leaf,
installation of an emergency disconnection device must be carried out (external lock to release
the drive rail).
Please, make sure that the socket is installed in such manner that after drive installation and con-
nection, the power cable is not within the door movement area or within reach of other moving
parts. The type of the power cable is H05VV-F 3G0.75 mm2, power cable plug—type E / F CEE 7 / 7.
Please, make sure that the mains supply is equipped with protective earthing.
Please, make sure, that the section of the mains supply, to which the drive is connected, is
equipped with the short circuit protection device (Residual Current Device (RCD) automatic
switch or another equivalent device). The distance between the terminals in the protection
tripping unit should be at least 3 mm.
The electric cable of the control and safety devices should be laid separately from the cables with
mains voltage. The cables should be protected from contact with any rough and sharp surfaces
by using corrugated tubes, pipes and cable ducts to lay the cables.
Use multicore cable with double insulation for electric connection of the drive system compo-
nents. The parameters of the electric cables used (section, number of wires, length etc.) should
comply with the connection diagram, device power, laying distance, way of laying, ambient
conditions.