ПРИВОД LG-500 | LG-500 DRIVE)
60
PREPARATION FOR ASSEMBLY
2.2
TECHNICAL SPECIFICATIONS
PARAMETER
LG-500
Maximum pulling force, N
500
Rated pulling force, N
180
Maximum door opening speed, m / s
0.14
Maximum speed with nominal tractive force, m / s
0.1
Power
230 V (± 10 %) / 50 Hz
Maximum power consumption at rated force, W
150
Maximum power consumption in standby mode
(without accessories), W
2
Maximum door area
*
, m
2
8.4
Maximum operation intensity, cycles / hour
10
Maximum non-stop operation, min
7
Time of illumination after the door stops moving
This parameter is regulated in the range
~ 0 … 500 s; default value is 30 s
Remote control
433.92 ± 0.075 MHz / dynamic code /
maximum 64 remote controls
Protection class
I
Protection degree
IP20
Working temperature range,° С
− 20…+ 50
Drive weight, kg
4.0
Y
ATTENTION!
Technical specifications are valid at ambient tempe 20 º С (± 5 º С).
PART NO.
RAIL TYPE
MAXIMUM DOOR HEIGHT, М *
LGR-3300B
belt
2400
LGR-3600B
2700
LGR-4200B
3300
LGR-3300C
chain
2400
LGR-3600C
2700
LGR-4200C
3300
The sizes (overall, connection, mounting dimensions), which are ensured by the scope of supply,
are presented in
fig
. 1.
3.
PREPARATION FOR ASSEMBLY
Y
ATTENTION!
Please check the condition of all components and materials for their suitability and
compliance with the applicable regulatory documents in force. The applied instruments and ma-
terials should be fully intact and comply with the safety norms, standards and instructions in force.
Please, make sure that the door construction is suitable for the automation. Please, make sure
that there is enough space for the drive system and its operation.
Please, make sure that the sizes of the door and the specifications are within the acceptable
limits (section 2.2 ‘Technical specifications’). Make sure that the installation site corresponds to
the declared temperature operating range indicated on the drive label.
* The data shown is for standard mounting of ALUTECH sectional garage doors.
Table 2 —
drives
Table 3 —
rails