ПРИВОД LG-500 | LG-500 DRIVE)
71
ADjUSTMENT
6.3
SETTINGS OF OPERATION VALUES
The
table 13
shows an example to enter the settings menu and to set the operation values.
1
Press and hold the button
for about 5 secs to enter the
programming mode
2
After the appearance of ‘
P1
’ inscription press the button
or
and select the required menu «
P№
»
3
After the appearance of the required menu inscription press the
button
4
With the button
or
select the required setting «
F№
»
5
After the appearance of the required setting inscription press the
button
6
The value of setting will be on a display. The value will be with a dot. With the
button
or
select the required value of setting
7
After the appearance of the required value of setting press the button
.
The value will be with a dot, that means the change the setting
8
To exit the programming mode press the button
three times or wait
for 15 seconds (until automatic exit the setup menu)
The
table 14
describes the settings, values of setting and default values for the drive supply.
MENU
SETTING
DESCRIPTION
VALUES
DEFAULT
VALUE
P1
F4
The adjustment of end positions
. The function
is designed to monitor and adjust the end
positions once every 100 cycles of raising and
lowering the gate (
fig
. 16)
no
—
OFF
/
on
—
ON
no.
P3
F1
Automatic mode
. The control is performed by
means of short presses on the control button
on.
F2
Manual mode
. Control is performed by means
of holding the control button in the pressed
state (buttons
or
and drive
connection ‘
SBS
’ output). The remote control
commands are not executed. Connected security
devices are activated. The manual mode disables
the automatic mode
no.
P4
F1
Pause time until automatic closing
no
—
OFF
/
00
,
01
…
99
00
—0 sec;
99
—99 secs
no.
F2
Pause time until automatic closing
after
photocells activation (the input connection ‘
PH1
’)
no.
Table 13
Table 14