T
ROUBLESHOOTING
Vector® F Series
▪
Service Manual
▪
MN-46896
▪
Rev 01
▪
07/20
77
Continued from previous page
Insert the
thermocouple
8.
Insert
the thermocouple from the multimeter into the heated oven. Allow the
multimeter to stabilize.
Compare
the reading from the multimeter’s thermocouple with the
temperature sensor reading displayed on the screen.
Calibrate the offset
9.
Calibrate
the offset number. Subtract the smaller value from the larger
value. This is the offset. If the value measured by the multimeter was the
larger value, the offset will positive “+”. If the value measured by the
multimeter was the smaller value, the offset will be negative “–”.
Continued on next page
VMC-TS-010923
450
º
F