T
ROUBLESHOOTING
Vector® F Series
▪
Service M anual
▪
MN-46896
▪
Rev 01
▪
07/20
78
Continued from previous page
10.
Enter
the offset. To do so:
Touch
the “>” icon
i
for the chamber offset temperature that needs to be
calibrated. The Enter offset screen displays.
Enter
the value calibrated in step 10 and press the check mark. The
multimeter temperature and the temperature sensor should show the same
reading.
11.
Repeat
the procedure for the remaining chambers.
12.
Cool
the oven.
Result
The chamber thermocouples have now been calibrated.
VMC-TS-010926