T
ROUBLESHOOTING
Vector® F Series
▪
Service Manual
▪
MN-46896
▪
Rev 01
▪
07/20
73
Continued from previous page
9.
Measure
the amp draw while the heater is on. The amperage draw of a
functioning heater element is 10-15 amps.
10.
Touch
the heater button
j
to stop the heater. The heater and convection
fan buttons will turn white.
11.
Cool
the oven.
12.
Re-install
the side panel.
Result
The heaters have now been tested.
WARNING:
Electric shock hazard. Wear PPE and use
best practices when measuring live voltage.
VMC-TS-010784
VMC-TS-010920
j