T
ROUBLESHOOTING
Vector® F Series
▪
Service M anual
▪
MN-46896
▪
Rev 01
▪
07/20
80
Continued from previous page
3.
Insert
the meter leads
c
into the probe connector. The measurement
should be between 99 and 101 ohms at 32°F (0°C).
Result
The probe has now been tested.
NOTE:
If the measurement is not between 99 and 101
ohms, replace the faulty probe.
VMC-TS-003723
c
100