The general function of the MAX/MAX II Configuration Controller is as follows:
•
SAFE
button loads the Factory default design (BTS design)
•
SYS_RESETn
button loads user design file located in the page
pointed to by
MPGM(2:0)
or
SPGM(2:0)
based on
MSEL2
(remote
configuration enable)
•
SAFE
design will be loaded if the User Design fails to load.
•
USER LEDs
are driven through the MAX/MAX II from the Stratix II
•
LOADING LED
blinks during a configuration attempt
•
CONF_DONEn LED
lights when the Factory Default image was
loaded
•
USER LED
lights when a User Design was loaded from any page
•
ERROR LED
lights when configuration failed.
Table 8 MAX/MAX II Design Detail