Problems
Possible Solutions
LEDs fail to come on when power is
applied
Check that main connector power supply is
properly connected to J2.
Check that switch SW1 is turned on (all the
way up).
Check that the power supply is plugged in
to wall.
Check the jumper settings as suggested in
Table 5.
Devices fail to configure
Check that correct program file is chosen.
Check that the USB Blaster cable is
installed correctly to J17 (check pin one
indicator on cable)
Check that the JTAG Bypass jumpers (J40)
are set appropriately.
Check that the board is put into SAFE
mode before loading each .bat file.
Design does not work properly
If using on-board oscillators, check that
jumpers (J36, J39) are placed across pins 1
and 2.
Check that cables are installed correctly.
Check that correct program file is chosen.
Check that correct push buttons and dip
switches are being used.
Check that dip switches, if used, are at the
correct values. See Table 3.
Ensure that the cards are fully seated
(DDR2 DIMM).
Check that the PROTO1 Test Card is
installed and fully seated.
RS-232 connection not working
Check that RS-232 connector is plugged
into correct port (on board and on PC).
Table 6 Troubleshooting
3.3
Diagnostic Test Details
3.3.1
User I/O & Nios Features Test
The User I/O and Nios® features of the Stratix® II Memory Board 2 are tested using a
Nios II-based system controlled by a host computer. The host computer runs the board
test system (BTS), and the tool command language (TCL)-based application using the
Quartus® II TCL application program interface (API). The BTS host application uses an
RS-232 cable connected to the Stratix II Memory Board 2 to communicate with the Nios
system.