Stratix II Memory Board 2 Rev A User Guide Rev 0.1
Altera Confidential
14
6. Verify that the tests complete without errors. The test results appear in the Nios Stamp
Msgs window, and should read as follows.
Starting Test
Walking Ones on Data
Starting Flash Erase of sector offset 0
Finished Flash Erase
Walking Ones on Address
Starting Flash Erase
Test Complete
7. Click the Get DHCP address button under Ethernet. If the board is connected to a live
network this test should return an internet protocol (IP) address. The test results appear in
the Nios Stamp Msgs window, and should read as follows:
Getting DHCP Address
DHCP Address obtained. Address is 137.57.185.70.
Note: The IP address returned may be different from the example above.
8. Click the Blink Ethernet LEDs button.
9. Verify that the LEDs on the Ethernet connector blink several times.
10. If the Stratix II high-speed development board is not connected to a live network, the
Ethernet tests cannot work correctly. In this case, look for the following message in the
BTS message window in the bottom of the GUI. It takes about 1 minute before you get
the first timing out message.
[lan91c111] nr_lan91c111_reset: chip id = LAN91C111
[lan91c111] r_lan91c111_detect_phy: found lan83C183 (lan91C111
internal)
[lan91c111] r_lan91c111_init_phy: phy negotiation timed out
[lan91c111] r_lan91c111_init_phy: 10bt
[lan91c111] r_lan91c111_init_phy: half duplex
[dhcp] 1 timing out
[dhcp] 2 timing out…
This finishes the NIOS Stamp section of the tests. This finishes the NIOS Stamp section
of the tests. Exit the GUI.
2.3.3
DDR2 SDRAM DIMM Test