Chapter 7: Custom PHY IP Core
7–5
Parameter Settings
March 2012
Altera Corporation
Altera Transceiver PHY IP Core
User Guide
Table 7–4
shows the resulting reset controller mode for various combinations of the
pma_rx_setlocktodata
and
pma_rx_set_locktoref
registers. As
Table 7–4
indicates,
setting either
pma_rx_setlocktodata
or
pma_rx_set_locktoref
disables the automatic
reset controller.
Avalon da
t
a in
t
e
r
faces
On/Off
When you turn this option
On
, the order of symbols is changed.
This option is typically required if you are planning to import your
Custom PHY IP core into a Qsys system.
Enable embedded
r
ese
t
con
tr
ol
On/Off
When
On
, the automatic reset controller resets your design at
power up. When
Off
you can design you own reset logic using
tx_analogreset
,
rx_analogreset
,
tx_digitalreset
,
rx_digitalreset
, and
pll_powerdown
which are top-level ports
of the Custom Transceiver PHY. You must turn this option
Off
to
implement your own reset controller.
By default, the CDR circuitry is in automatic lock mode whether you
use the embedded reset controller or design your own reset logic.
You can switch the CDR to manual mode by writing the
pma_rx_setlocktodata
or
pma_rx_set_locktoref
registers
to 1. If either the
pma_rx_set_locktodata
and
pma_rx_set_locktoref
is set, the CDR automatic lock mode is
disabled as
Table 7–4
illustrates. For more information about the
reset control and status registers, refer to
Table 7–21 on
page 7–21
.
For more information about reset in Stratix V devices, refer to
Transceiver Reset Control in
S
tratix V Devices
in volume 3 of the
S
tratix V Device Handbook
.
Table 7–3. General Options (Part 3 of 3)
Name
Value
Description
Table 7–4. Reset Mode
rx_set_locktoref
rx_set_locktodata
CDR Lock Mode
1
0
Manual RX CDR locked to reference
X
1
Manual RX CDR locked to data
0
0
Automatic RX CDR