Chapter 5: Clock Networks and PLLs in Arria II Devices
5–47
PLLs in Arria II Devices
December 2010
Altera Corporation
Arria II Device Handbook Volume 1: Device Interfaces and Integration
shows the scan chain order of Arria II GX PLL components which have
seven post-scale counters. The reconfiguration bits start with the
C6
post-scale
counter.
shows the scan chain order of PLL components for the top and bottom
Arria II GZ PLLs.
shows the scan chain bit-order sequence for post-scale counters in all
Arria II PLLs.
Figure 5–37. Scan Chain Order of PLL Components for Arria II GX PLLs
DATAIN
MSB
LF
K
CP
LSB
N
M
C0
C1
C2
C3
C4
C5
C6
DATAOUT
Figure 5–38. Scan Chain Order of PLL Components for Top and Bottom of Arria II GZ PLLs
Note to
:
(1) Left and right PLLs have the same scan chain order. The post-scale counters end at C6.
DATAIN
MSB
LF
K
CP
LSB
N
M
C0
C1
C2
C3
C4
C5
C6
C7
C8
DATAOUT
C9
Figure 5–39. Scan Chain Bit-Order Sequence for Post-Scale Counters in Arria II PLLs
DATAIN
rbypass
HB
7
HB
6
HB
5
HB
4
HB
3
HB
2
HB
1
HB
0
rselodd
LB
7
LB
6
LB
5
LB
4
LB
3
LB
2
LB
1
LB
0
DATAOUT