13.4 Display Screen Not Functioning
Possible Cause
Check
Corrective Action
Dryer experienced a
power spike
Power the air dryer
OFF
for 15+ seconds.
Power the air dryer
ON
.
Ribbon cable
disconnected
Verify ribbon cable
from the decal is
connected at the display
board
Reconnect the ribbon
cable properly.
13.5 High Outlet Pressure Alarm
Possible Cause
Check
Corrective Action
Outlet Pressure set too
high
Verify Outlet Pressure
(
OUTP
) reading
(section 8.2.5.1 )
Adjust Outlet Pressure
Regulator (section
Error! Reference
source not found.
)
High Outlet Pressure
Alarm set point too low
Verify High Outlet
Pressure Alarm set point
(section
Error!
Reference source not
found.
)
Raise High Outlet
Pressure Alarm set point
(section
Error!
Reference source not
found.
)
13.6 Can’t Create a High Pressure Alarm
Possible Cause
Check
Corrective Action
Defective Outlet
Pressure Regulator
Verify that the Outlet
Pressure Regulator can
be adjusted
(section
Error!
Reference source not
found.
)
Replace Outlet Pressure
Regulator if unable to
adjust pressure
(section11.2 )
High Outlet Pressure
Alarm set point higher
than default setting
Verify High Outlet
Pressure Alarm set point
(section
Error!
Reference source not
found.
)
Adjust Outlet Pressure
Regulator so that Outlet
Pressure (
OUTP
)
reading climbs over
verified set point
(section 9.14 )
Defective Control Board Verify that the Outlet
Pressure (
OUTP
)
reading is higher than
Replace Control Board
(section 11.2 ) if Outlet
Pressure (
OUTP
)