ALTEC AIR, LLC
P1500W Series Air Dryers User’s Guide
Page 60 of 101
P011787 – Rev. R
When the Compressor should NOT be running
:
9.5.5
Use a Voltmeter to measure
across the AC terminals.
Should measure:
110 - 125 VAC
for the
P1500W, P1500WLP &
P1500WHP models
208 - 230 VAC
for the
P1502W, P1502WLP& P1502WHP models
9.5.6
Use a Voltmeter to measure across the DC terminals.
Should measure
0 VDC
.
9.5.7
Close Front Panel.
If any of the AC voltage measurements are different than indicated above, the
Solid State Relay is defective and should be replaced.
If any of the DC voltage measurements are different that indicated above, the
Control Board may be defective and should be replaced.
See sections 11.1 for part detail and 11.5 for ordering information.