Reference source not
found.
)
Air leak inside of dryer
Test fittings and hoses
for leaks (section 9.16 )
Reconnect or replace
bad fitting / hose
High Flow Alarm set
point too low
Verify High Flow Alarm
set point
(section
Error!
Reference source not
found.
)
Raise High Flow Alarm
set point (section
Error!
Reference source not
found.
)
13.12 High Cabinet Temperature Alarm
Possible Cause
Check
Corrective Action
Fan Failure
Verify fan is running
(section 9.9 )
Check for loose fan
wiring (section 14.1 )
Replace defective fan
(section 11.1 )
High Ambient
Temperature
Verify temperature of
dryer operating location.
Recommended ambient
temperature is 40°-85°F.
Lower the ambient
temperature of the
dryer’s operating
location
13.13 Inconsistent Heatless Dryer Cycling
Possible Cause
Check
Corrective Action
Defective Solenoid
Valve
Measure voltage going
to the Heatless Dryer
Solenoid Valves
(section 9.8 )
If voltage
IS
present,
replace Solenoid Valves
included in the 8,000
Hour Maintenance Kit
(section 11.4 )
Defective Cycle Timer
Measure voltage going
to the Heatless Dryer
Solenoid Valves
(section 9.8 )
If voltage
IS NOT
present, replace the
Cycle Timer
(section 11.3 )
13.14 Compressor Doesn’t Operate
Possible Cause
Check
Corrective Action
System is in Shutdown
state
On the Display Panel,
verify that the system is
in
SHUTDOWN
state
Press the
RESET
Button
Defective Compressor
Measure Compressor
voltage
(section 9.3 )
If voltage is good,
replace Compressor
(section 11.2 )
or send it in for repair