ALTEC AIR, LLC
P1500W Series Air Dryers User’s Guide
Page 64 of 101
P011787 – Rev. R
9.7.5
With a 9/16” wrench
connect hose to the Unloader
Valve.
9.7.6
Close Front Panel.
9.8 Measuring Heatless Dryer
Solenoid Voltage
With the Compressor running
:
9.8.1
Open Front Panel (section 8.6 ).
9.8.2
Locate the Heatless Dryer
Cycle Timer.
The timer has three (3) sets of
terminals (from left-to-right):
“
VALVE
” – Left solenoid
“
IN
” – Incoming power
“
VALVE
” – Right solenoid
9.8.3
Use a Voltmeter to measure
the DC voltage across each
set of “
VALVE
” terminals.
Continue to measure for up to
45 seconds if no voltage is
initially measured.
The voltage should measure:
53 VDC
for the P1500W, P1500WLP & P1500WHP models
Содержание PUREGAS P1500W Series