Chapter 5
– Operation
RPV311
148
RPV311-TM-EN-6
Figure 65: Monitoring circuit quantities via Web interface
A
Phasor angle for each phase of the selected circuit.
B
Selected circuit to be monitored.
C
Quantities related to the circuits being monitored.
Phasor angles measured and displayed are absolute angles referenced to the PPS signal provided by the
synchronization. When no sync signal is connected, the measured angles are referenced to Phase A of the
reference circuit.
Values are updated at the rate of 2 points per second, however, when two or more circuits are
simultaneously displayed, their time stamps may not be related to each other.
Note: The RPV311 has an autozero automatic feature, which is a slow filter that takes about 15 minutes to
filter the DC components of the reading signal and then subtracts it from the readings in order to locate the
correct position of the signal reference on the graph. The response of the filter is stored in the solid memory
with the purpose of turning this process faster for subsequent reboots on the device. This filter will not
interfere with the registering of the DC components generated by faults.
Содержание Reason RPV311
Страница 2: ......
Страница 15: ...INTRODUCTION CHAPTER 1...
Страница 34: ...SAFETY INFORMATION CHAPTER 2...
Страница 45: ...HARDWARE DESIGN CHAPTER 3...
Страница 56: ......
Страница 57: ...CONFIGURATION CHAPTER 4...
Страница 75: ...RPV311 Chapter 4 Configuration RPV311 TM EN 6 75 Figure 21 Email Fax configuration...
Страница 77: ...RPV311 Chapter 4 Configuration RPV311 TM EN 6 77 Figure 22 Adding and editing voltage circuits...
Страница 117: ...OPERATION CHAPTER 5...
Страница 121: ...RPV311 Chapter 5 Operation RPV311 TM EN 6 121 Figure 46 Status monitoring sequence...
Страница 123: ...RPV311 Chapter 5 Operation RPV311 TM EN 6 123 Figure 47 Monitoring sequence...
Страница 126: ...Chapter 5 Operation RPV311 126 RPV311 TM EN 6 Figure 49 Records monitoring sequence harmonics flicker and SOE...
Страница 128: ...Chapter 5 Operation RPV311 128 RPV311 TM EN 6 Figure 50 Equipment settings monitoring sequence...
Страница 129: ...RPV311 Chapter 5 Operation RPV311 TM EN 6 129 Figure 51 Circuit and channel settings monitoring sequence...
Страница 130: ...Chapter 5 Operation RPV311 130 RPV311 TM EN 6 Figure 52 Relays PMU and MODBUS settings monitoring sequence...
Страница 132: ...Chapter 5 Operation RPV311 132 RPV311 TM EN 6 Figure 53 General information monitoring sequence...
Страница 155: ...RECORDS CHAPTER 6...
Страница 172: ......
Страница 173: ...TW FAULT LOCATOR CHAPTER 7...
Страница 183: ...PMU CHAPTER 8...
Страница 189: ...MODBUS CHAPTER 9...
Страница 193: ...DNP3 CHAPTER 10...
Страница 196: ......
Страница 197: ...GOOSE MESSAGE DETECTION CHAPTER 11...
Страница 200: ......
Страница 201: ...SOFTWARE RPV TOOLS CHAPTER 12...
Страница 228: ......
Страница 229: ...SOFTWARE RPV MANAGER CHAPTER 13...
Страница 249: ...COMMUNICATIONS CHAPTER 14...
Страница 261: ...INSTALLATION CHAPTER 15...
Страница 295: ...Chapter 15 Installation RPV311 RPV311 TM EN 6 295 Figure 138 RA331 RA332 and RA333 dimensions...
Страница 299: ...MAINTENANCE AND TROUBLESHOOTING CHAPTER 16...
Страница 310: ...TECHNICAL SPECIFICATIONS CHAPTER 17...
Страница 329: ...Chapter 17 Technical Specifications RPV311 RPV311 TM EN 6 329 Figure 142 RA331 RA332 and RA333 dimensions...
Страница 331: ...RPV311 Chapter 17 Wiring Diagrams WIRING DIAGRAMS CHAPTER 18...
Страница 340: ...APPENDIX A...