Parameter Setting
This page is to activate some features and set up parameters for inverters. Please note that the listing in
“Parameter Setting” page in below diagram may differ from the models of monitored inverter. Here will briefly
highlight some of it,
【
Output Setting
】
,
【
Battery Parameter Setting
】
,
【
Enable/ Disable items
】
,
【
Restore
to the defaults
】
to illustrate.
There are three ways to modify setting and they vary according to each parameter.
a)
Listing options to change values by tapping one of it.
b)
Activate/Shut down functions by clicking
“Enable” or “Disable” button.
c)
Changing values by clicking arrows or entering the numbers directly in the column.
Each function setting is saved by clicking “Set” button.
Please refer to below parameter setting list for an overall description and be noted that the available
parameters may vary depending on different models. Please always see the original product manual for
detailed setting instructions.
Parameter setting list:
Item
Description
Output setting
Output source
priority
To configure load power source priority.
AC input range
When selecting "UPS", it's allowed to connect personal computer.
Please check product manual for details.
When selecting "Appliance", it's allowed to connect home
appliances.
Output voltage
To set output voltage.
Output
frequency
To set output frequency.
Battery
parameter
setting
Battery type:
To set connected battery type.
Battery cut-off
voltage
To set the battery stop discharging voltage.
Please see product manual for the recommended voltage range
based on connected battery type.
Back to grid
voltage
When
“SBU” or “SOL” is set as output source priority and battery
voltage is lower than this setting voltage, unit will transfer to line
mode and the grid will provide power to load.
Back to
discharge
voltage
When “SBU” or “SOL” is set as output source priority and battery
voltage is higher than this setting voltage, battery will be allowed to
discharge.