Item
Description
Battery
parameter
setting
Charger source
priority:
To configure charger source priority.
Max. charging
current
It’s to set up battery charging parameters. The selectable values in
different inverter model may vary.
Please see product manual for the details.
Max. AC
charging
current:
Float charging
voltage
Bulk charging
voltage
It’s to set up battery charging parameters. The selectable values in
different inverter model may vary. Please see product manual for
the details.
Battery
equalization
Enable or disable battery equalization function.
Real-time
Activate Battery
Equalization
It’s real-time action to activate battery equalization.
Equalized Time
Out
To set up the duration time for battery equalization.
Equalized Time
To set up the extended time to continue battery equalization.
Equalization
Period
To set up the frequency for battery equalization.
Equalization
Voltage
To set up the battery equalization voltage.
Enable/Disable
Functions
LCD
Auto-return to
Main screen
If enable, LCD screen will return to its main screen after one minute
automatically.
Fault Code
Record
If enabled, fault code will be recorded in the inverter when any fault
happens.
Backlight
If disabled, LCD backlight will be off when panel button is not
operated for 1 minute.
Bypass
Function
If enabled, unit will transfer to line mode when overload happened
in battery mode.
Beeps while
primary source
interrupt
If enabled, buzzer will alarm when primary source is abnormal.
Over
Temperature
Auto Restart
If disabled, the unit won't be restarted after over-temperature fault is
solved.
Overload Auto
Restart
If disabled, the unit
won’t be restarted after overload occurs.
Buzzer
If disabled, buzzer
won’t be on when alarm/fault occurred.
RGB LED
Setting
Enable/disable
Turn on or off RGB LEDs
Brightness
Adjust the lighting brightness
Speed
Adjust the lighting speed
Effects
Change the light effects
Color selection
Adjust color combination to show energy source an battery status
Restore to the
default
This function is to restore all settings back to default settings.
Worldwide Corporate Offices
Headquarter Germany
Hansastrasse 8
D-91126 Schwabach
Tel: +49 9122 79889 0
Fax: +49 9122 79889 21
Mail: [email protected]
Eastern Europe
Middle East
France and Benelux
Spain
Africa
Alpha and Outback Energy GmbH reserves the right to make changes to the products and information contained in this document without notice. Copyright © 2020 Alpha and Outback Energy GmbH. All Rights
reserved.
For more information, please visit
User
M
a
n
u
a
l:
r
e
v
A
_
2
5
2
2