Hook the control panel's hooks into the recesses
of the front panel (either in the upper or lower
recesses)...
Example:
control panel in upper recesses
push down the hooked in control panel, until it
latches into place…
push the control cable of the heating and heat
pump controller into the
right-hand
socket on the
underside of the control panel…
note.
A connection to a computer or a network can
be made via the left socket at the bottom of the
control panel, thereby allowing the heating and
heat pump controller to be controlled remotely
from there. This requires a shielded network
cable (category 6) to be laid through the unit
during the electrical connection work.
operating manual for the heating and heat pump
controller, “qualified technician” version, “Web
server” section.
If this network cable is available, insert the
network cable's RJ-45 connector into the left
socket of the control panel.
note.
The network cable can be exchanged at any
time. In order to be able to connect it, the
screen must first be removed.