Alpha-InnoTec LW 161H/V Скачать руководство пользователя страница 30

30

Subject to change without notice  |  83061600bUK  |  ait-deutschland GmbH

Pos. Name

1

Control unit

2

Heating water outlet (flow)

G 5⁄4ʺ DIN ISO 228

3

Heating water inlet (return)

G 5⁄4ʺ DIN ISO 228

4

Bushings for electrical / sensor cables

5

Condensate hose

 

Length from unit: 1 m

Ø-inside 30

 

Keys: UK819356a

All dimensions in mm.
Pos. Name

A

Front view

B

Side view from the left

D

Side view from the right

E

Rear view

LR

Air direction

Dimensioned drawings

LW 161HL/V

Содержание LW 161H/V

Страница 1: ...UK 83061600bUK Air Water Heat Pumps Indoor installation Operating Manual LW 161H L V...

Страница 2: ...ith the unit Treat all its constituent parts confidentially They are protected by copyright They may not be reproduced transmitted copied stored in electronic systems or translated into another langua...

Страница 3: ...ng and venting the system 20 24 Insulating the hydraulic connections 20 25 Installing the control unit 21 26 Installation and removal of the screen 22 27 Overflow valve 23 28 Commissioning 24 29 Maint...

Страница 4: ...ended for all users of the product The operation of the product via the heating and heat pump control and work on the product which is intend ed for end customers operators is suitable for all age gro...

Страница 5: ...prevent injuries caused by the rotating fan air duct outlet above ground level weather louvre air duct outlet below ground level rain louvre each not included in the accessories supplied IMPORTANT It...

Страница 6: ...he same technology only with reversed benefits The refrigerator extracts heat from food It discharges this heat into the room through fins at its rear The heat pump extracts heat from our environment...

Страница 7: ...the control element of the heating and heat pump controller to operate and control the heat pump system NOTE Make sure that the controller settings are correct Operating manual of the heating and hea...

Страница 8: ...ery for outwardly visible signs of damage 2 Check to make sure that the delivery is complete Any defects or incorrect deliveries must be report ed immediately NOTE Note the unit model Check the direct...

Страница 9: ...plans for air water heat pumps The respective regional regulations must be observed Installation room and space requirements NOTE Note and follow the local regulations and standards regarding the ins...

Страница 10: ...can also transport the heat pump on a handcart or with tube handles Lifting the unit with tube handles page 10 WARNING The unit is not fixed on the wooden pallet Risk of tipping overturning during tra...

Страница 11: ...tion Make sure that the unit s baseframe is in full contact with the surface of the floor 7 Remove the tube handles 8 If the electrical connection work is not carried out immediately re attach the low...

Страница 12: ...hem in a safe place 5 At the fan thread in the two guide rods supplied with the unit through the metal tab and fan Then on both sides hook the guide rods in the key hole perforation of the top metal t...

Страница 13: ...stening nuts on the top metal tab and remove the corresponding bolts Then pull the fan out of the unit and bolt it back onto the unit frame do not forget the spring lock washers 10 Remove the guide ro...

Страница 14: ...rence between the vertical centre of the air duct connections on the unit and the top edge of the air inlet air out let on the building must not exceed 2 m 4 Turn the already pushed together parts thr...

Страница 15: ...ip on the mounting strip and use special screws to fix onto the places provided for this purpose on the air duct for the air inlet side 2 Glue the connection frame supplied onto the edge of the air du...

Страница 16: ...procedure 2 4 at the air outlet side Installing the frame trim Screw the frame trim onto the wall penetration on the air inlet and air outlet side NOTE The frame trim does not fulfil any technical fu...

Страница 17: ...heating circuit IMPORTANT Integrate the unit in the heating circuit as shown in the hydraulic diagram for the respective unit model It is not possible to connect several heat pumps in parallel Hydrau...

Страница 18: ...d guidelines Also install filling and draining emptying devices shut off devices and non return valves in the heating circuit 18 Circulation pump The circulation pump is installed in the unit Only one...

Страница 19: ...ned draw ing for the respective unit model 3 2 Push the cables through the rubber grommets in the unit By pushing them in the cables are routed inside the unit in a closed cable duct to the terminals...

Страница 20: ...nly low salt operation of the system Advantages of low salt operation Low corrosion promoting properties No formation of mineral scale Ideal for closed heating circuits Ideal pH value due to self alka...

Страница 21: ...to position 3 Push the control cable of the heating and heat pump controller into the right socket on the un derside of the control unit NOTE A connection to a computer or a network can be made via th...

Страница 22: ...ment 2 logo 3 temporary cover 1 First insert the screen below in the provided slots on the front of the facade 2 Beginning first on one side and moving upwards lock the screen s snap in lugs in place...

Страница 23: ...ivated The UWP control signal is the indication of the currently required pump capacity in If the flow rate is the current flow rate measuring accuracy 200 l h 1 Fully open the overflow valve close th...

Страница 24: ...rer s factory customer service department In other countries Send completion report for heat pump systems and general checklist to the manufacturer s local partner 4 The heat pump system is commission...

Страница 25: ...al cleaning agent any residues must be neu tralised and the system flushed intensive ly with water Always note and follow the technical data of the respective heat ex changer manufacturer 30 Malfuncti...

Страница 26: ...tling DANGER Risk of fatal electric shock All electrical connection work must be carried out by qualified electricians only Before opening the unit disconnect the system from the power supply and prev...

Страница 27: ...perating pressure bar 3 Circulation pump control range min I max l h 1000 2000 General unit data Total weight kg 367 Weight of heat pump module Compact module Fan module kg kg kg Refrigerant type Refr...

Страница 28: ...1 823295 Legende NEU Volumenstrom Heizwasser Temp Temperatur W rmequelle Qh min max minimale und maximale m gliche Heizleistung p Freie Pressung W rmepumpe LW 160H L V 823295 Datei 823295 Leistungs Dr...

Страница 29: ...5 4 DIN ISO 228 3 Heating water inlet return G 5 4 DIN ISO 228 4 Bushings for electrical sensor cables 5 Condensate hose Length from unit 1 m inside 30 Keys UK819355a All dimensions in mm Pos Name A F...

Страница 30: ...5 4 DIN ISO 228 3 Heating water inlet return G 5 4 DIN ISO 228 4 Bushings for electrical sensor cables 5 Condensate hose Length from unit 1 m inside 30 Keys UK819356a All dimensions in mm Pos Name A F...

Страница 31: ...installation in the light well Tipping dimension of the heat pump 2050 Pos Name Dim B1 If finished wall thickness 240 to 320 2340 If finished wall thickness 320 to 400 2260 B2 If finished wall thickn...

Страница 32: ...installation in the light well Tipping dimension of the heat pump 2050 Pos Name Dim B1 If finished wall thickness 240 to 320 2340 If finished wall thickness 320 to 400 2260 B2 If finished wall thickne...

Страница 33: ...the light well Tipping dimension of the heat pump 2050 Pos Name Dim B2 If finished wall thickness 240 to 320 390 If finished wall thickness 320 to 400 310 1 Accessories Wall duct 1000x1000x420 3 Acce...

Страница 34: ...densate drain G Detail of installation in the light well Tipping dimension of the heat pump 2050 Pos Name Dim B2 If finished wall thickness 240 to 320 390 If finished wall thickness 320 to 400 310 1 A...

Страница 35: ...LW 161H L V IMPORTANT The minimum distances necessary for correct and safe operation as well as any service work must be ob served 9 Air intake on the side facing away from the coast from the prevaili...

Страница 36: ...36 Subject to change without notice 83061600bUK ait deutschland GmbH Row tank LW 161H L V...

Страница 37: ...37 Subject to change without notice 83061600bUK ait deutschland GmbH 23 ZUP Separate buffer tank LW 161H L V...

Страница 38: ...mfort board Expansion board 29 Dirt trap 0 6 mm mesh 15 Mixer circuit three way mixer MK2 3 discharge r o t a l u g e r e c n e r e f f i d e r u t a r e p m e T 7 1 l a n o i t p o g n i l o o c r o...

Страница 39: ...xiliary circulation pump Accessories Process water sensor thermostat Heating circuit circulating pump External sensor Hot water gauge thermostat Sensor mixing circuit 1 External return sensor Return s...

Страница 40: ...rminal in switch box heat pump 1 G1 E23 F6 PFC X10 3 M1 R6 F1 1 2 3 4 5 6 7 8 1 2 8 A B C D E F A B C D E F Blatt Bl 1 4 3 4 5 6 7 AIT Stromlaufplan ait deutschland GmbH PEP012 2017 08 01 2018 AP 1N P...

Страница 41: ...J20 STB Q6 J15 J22 X20 J11 K22 J7 K23 1 2 3 4 5 6 7 8 1 2 8 A B C D E F A B C D E F Blatt Bl 2 4 3 4 5 6 7 AIT Stromlaufplan ait deutschland GmbH PEP012 2017 08 01 2018 AP N 1 A4 L L N N PE PE 1 B3 13...

Страница 42: ...sensor Heat source input sensor B10 817453b B11 J13 X100 R3 R2 R1 J21 R5 R4 SEC Board 1 2 3 4 5 6 7 8 1 2 8 A B C D E F A B C D E F Blatt Bl 3 4 3 4 5 6 7 AIT Stromlaufplan ait deutschland GmbH PEP01...

Страница 43: ...Blatt Bl 4 4 3 4 5 6 7 AIT Stromlaufplan ait deutschland GmbH PEP012 2017 08 01 2018 AP PE 2 D6 N 2 D6 L 2 D6 PE N L br bl HUP PE OUT8 OUT7 OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 N N L IN1 IN2 IN3 IN4 IN5 L L...

Страница 44: ...44 Subject to change without notice 83061600bUK ait deutschland GmbH...

Страница 45: ...45 Subject to change without notice 83061600bUK ait deutschland GmbH...

Страница 46: ...46 Subject to change without notice 83061600bUK ait deutschland GmbH...

Страница 47: ...47 Subject to change without notice 83061600bUK ait deutschland GmbH...

Страница 48: ...ait deutschland GmbH Industriestra e 3 D 95359 Kasendorf E info alpha innotec de W www alpha innotec de alpha innotec an ait deutschland GmbH brand UK...

Отзывы: