![Alpha-InnoTec LW 161H/V Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/alpha-innotec/lw-161h-v/lw-161h-v_operating-manual_2906085027.webp)
27
Subject to change without notice | 83061600bUK | ait-deutschland GmbH
Performance data
Values in brackets: (1 Compressor)
LW 161H(L)/V
Heating capacity | COP
for A10/W35 acc. to DIN EN14511-x: 2013
Partial load operation
kW | COP
10.0 I 4.87
for A7/W35 acc. to DIN EN14511-x: 2013
Partial load operation
kW | COP
5.8 I 4.33
for A7/W55 acc. to DIN EN14511-x: 2013
Partial load operation
kW | COP
9.1 I 2.73
for A2/W35 acc. to DIN EN14511-x: 2013
Partial load operation
kW | COP
8.1 I 4.20
for A-7/W35 acc. to DIN EN14511-x: 2013
Full load operation
kW | COP
13.9 I 3.21
for A-7/W55 acc. to DIN EN14511-x: 2013
Full load operation
kW | COP
14.7 I 2.41
Heating capacity
for A10/W35
min. I max.
kW | kW
5.8 | 17.4
for A7/W35
min. I max.
kW | kW
5.6 | 16.1
for A7/W55
min. I max.
kW | kW
6.5 | 17.1
for A2/W35
min. I max.
kW | kW
4.9 | 14.2
for A-7/W35
min. I max.
kW | kW
4.0 | 13.9
for A-7/W55
min. I max.
kW | kW
4.0 | 14.7
Cooling capacity | EER
for A35/W18
Partial load operation
kW | EER
– | –
for A35/W7
Partial load operation
kW | EER
– | –
Cooling capacity
for A35/W18
min. I max.
kW | kW
– | –
for A35/W7
min. I max.
kW | kW
– | –
kW
12
Operating limits
Heating circuit return min. | Heating circuit flow max. Heating
within heat source min./max.
°C
20 | 60
Heat source, heating
min. I max.
°C
-20 | 35
Additional operating points
…
A>-15 / W65
Sound
Sound power level inside
min. | Night | max.
dB(A)
35 | – | 53
Sound power level outside 1)
min. | Night | max.
dB(A)
31 | – | 48
Sound power level acc. to DIN EN 12102-1:2017
inside | outside
dB(A)
44 | 47
Tonality | Low-frequency
dB(A) | • yes – no
– | –
Heat source
Air flow rate at maximum external pressing | Maximum external pressure
m³/h | Pa
4400 | 25
Heating circuit
Flow rate (pipe dimensioning) I Min. volume buffer tank in series I Min. volume separation buffer tank
l/h | l | l
2000 | 200 | 200
Free pressing | Pressure loss | Flow rate
bar | bar | l/h
0.513 | 0.157 | 2000
Max. allowable operating pressure
bar
3
Circulation pump control range
min. I max.
l/h
1000 | 2000
General unit data
Total weight
kg
367
Weight of heat pump module | Compact module | Fan module
kg | kg | kg
– | – | –
Refrigerant type | Refrigerant capacity
… | kg
R410A | 4.00
Electrics
Voltage code | all-pole fuse protection for heat pump *)**)
… | A 3~/N/PE/400V/50Hz | C25
Voltage code | Control voltage fuse protection **)
… | A 1~N/PE/230V/50Hz | B16
Voltage code | Electric heating element fuse protection **)
1 phase
… | A
—
—
Voltage code | Electric heating element fuse protection **)
3 phases
… | A 3~/N/PE/400V/50Hz | B16
—
HP*): effect. Power consumption A7/W35 (partial load operation) DIN EN14511-x: 2013 I Electric consumption I cosφ
kW | A | …
0.82 | 3.7 | 0.97
HP*): effective power consumption A7/W35 acc. to DIN EN14511-x: 2013: min. I max.
kW | kW
1.40 | 4.30
HP*): Max. machine current I Max. power consumption within the operating limits
A | kW
22 | 8.0
Starting current: direct | with soft starter
A | A
5 | –
Degree of protection
IP
20
Residual current circuit breaker
if required
type
B
Electric heating element output
3 | 2 | 1 phase
kW | kW | kW
9 | 6 | 3
Circulation pump power consumption, heating circuit
min. I max.
W
5 | 87
Other unit information
Safety valve heating circuit | Response pressure
included in scope of supply: • yes – no | bar
– | –
Buffer tank | Volume
included in scope of supply: • yes – no | l
– | –
Heating circuit expansion vessel | Volume | Prepressure
incl. in scope of supply: • yes – no | l | bar
– | – | –
Overflow valve | Changeover valve heating - domestic hot water
integrated: • yes – no
– | –
Heating circuit vibration decoupling
incl. in scope of supply or integrated: • yes – no
–
Controller I Heat quantity recording I Extension board
incl. in scope of supply or integrated: • yes – no
• | • | –
813583a
*) compressor only, **) note local regulations 1) Indoor and outdoor installation.
For indoor installation: Intake 1.5m air duct, Blow-out 1.5m air duct + air duct bend (original accessories)
The performance data and the operating limits apply to clean heat exchangers l Index: h
Heating capacity domestic hot water preparation
Technical data / Scope of supply
Содержание LW 161H/V
Страница 1: ...UK 83061600bUK Air Water Heat Pumps Indoor installation Operating Manual LW 161H L V...
Страница 36: ...36 Subject to change without notice 83061600bUK ait deutschland GmbH Row tank LW 161H L V...
Страница 37: ...37 Subject to change without notice 83061600bUK ait deutschland GmbH 23 ZUP Separate buffer tank LW 161H L V...
Страница 44: ...44 Subject to change without notice 83061600bUK ait deutschland GmbH...
Страница 45: ...45 Subject to change without notice 83061600bUK ait deutschland GmbH...
Страница 46: ...46 Subject to change without notice 83061600bUK ait deutschland GmbH...
Страница 47: ...47 Subject to change without notice 83061600bUK ait deutschland GmbH...