8.11 Rear feed-out elevator (where fitted)
An elevator system requires regular maintenance in order to achieve optimal performance.
Every week, the elevator needs to be checked to make sure that the belt is running straight
and not wearing unevenly on one side. If the belt is not running straight, adjust the tension
by adjusting the tensioner nut on the side, and run it again to check.
The elevator surface should be kept clean at all times to keep feed from building up and
falling into the rollers during operation. Do not allow old feed to build up on the sides of the
belt.
Each week, ensure that the bearings are greased (as per Figure 17 below). Ensure that the
elevator is free-moving in each direction and that there is no feed caught in the slideways.
Replace belts and side rubbers when they become worn; otherwise, the elevator will not
function properly. Refer to the Rear Feed-Out Operator Manual Supplement for spare parts,
maintenance and operation
Figure 17: Rear feed-out elevator greasing points
8.12 Side and stub feed-out elevator (where fitted)
An elevator system requires regular maintenance in order to achieve optimum performance.
Every week, the elevator should be checked to make sure that the belt is running straight
and not wearing unevenly on one side. If the belt is not running straight, then adjust the
tension by adjusting the tensioner nut on the side, and run it again to check.
The elevator surface needs to be kept clean at all times in order to keep feed from building
up and falling into the rollers during operation. Do not allow old feed to build up on the sides
of the belt.
Each week, ensure that the bearings are greased, as per Figure 18 and 18a below. Ensure
that the elevator is free-moving in each direction and there is no feed caught in the
slideways.
Replace belts and side rubbers when they become worn; otherwise, elevator will not function
properly.
Grease point
Grease point
Grease point
Grease point
Содержание KEENAN MechFiber380
Страница 2: ...KEENAN MechFiber380 Operator s Manual Revision D02 09th Sept 2020 2...
Страница 37: ...KEENAN MechFiber380 Operator s Manual Revision D02 09th Sept 2020 37 PART II Spare Parts...
Страница 43: ...KEENAN MechFiber380 Operator s Manual Revision D02 09th Sept 2020 43 11 5 Standard feed out parts...
Страница 46: ...KEENAN MechFiber380 Operator s Manual Revision D02 09th Sept 2020 46...
Страница 73: ...KEENAN MechFiber380 Operator s Manual Revision D02 09th Sept 2020 73...