Bypass
3-7
SG-9500 Hardware Guide
HD 16 Fiber Bypass Unit Front Panel Connectors
•
Network Ports 1-16
connect to your network.
These ports are split into
eight blocks of four, each representing a link. Be sure to insert the Internal
and External connectors into the correct ports on the Bypass Unit. Internal
is on the left of each link and External is on the right. In addition please
note that the in each Duplex LC connector on the Bypass unit’s front panel
the Tx connector is the left LC connector and the Rx is the right LC
connector.
•
System Ports 1-16
connect to the SG-9500.
Be sure to insert the Internal
and External connectors into the correct ports on the Bypass Unit. Internal
is on the left of each link and External is on the right. In addition, please
note that the in each Duplex LC connector on the Bypass unit’s front panel
the Tx connector is the left LC connector and the Rx is the right LC
connector.
•
Primary
connects to the USB port on the SG-9500
•
Secondary
is not in use.