background image

 

 
Open Applications Interface (OAI) Gateway 
Installation and Setup 

Link Wireless Telephone System 
Link 150 MCU 
 

Part Number: 72-0075-07 

Issue B 

 

Summary of Contents for MOG500

Page 1: ...Open Applications Interface OAI Gateway Installation and Setup Link Wireless Telephone System Link 150 MCU Part Number 72 0075 07 Issue B ...

Page 2: ...ity response time performance suitability for use or performance of products described herein shall be deemed to be a warranty by SpectraLink for any purpose or give rise to any liability of SpectraLink whatsoever In no event shall SpectraLink be liable for any incidental indirect special or consequential damages whatsoever including but not limited to lost profits arising out of or related to thi...

Page 3: ...sions requirements Note concerning the Wireless Telephone and Base Stations This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation WARNING Changes or modifications to this equipment not ap...

Page 4: ... determine the maximum REN for your calling area If your telephone equipment causes harm to the telephone network the telephone service may discontinue your service temporarily If possible they will notify you in advance But if advance notice isn t practical you will be notified as soon as possible You will be informed of your right to file a complaint with the FCC Your telephone company may make ...

Page 5: ...er Any repairs or alterations made by a user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be...

Page 6: ...7 1 3 Installation Overview 7 2 OAI OVERVIEW 8 2 1 System Diagram 8 2 2 The OAI Gateway s Front Panel 9 3 INSTALLING THE OAI GATEWAY 10 3 1 Mount OAI Gateway to Wall 10 3 2 Conduct Power on Test 10 3 3 Connect the OAI Gateway to the MCU 11 3 4 Connect the OAI Gateway to the Application Server 12 4 ASSIGN OAI FUNCTION KEY 13 5 CERTIFICATION TEST 14 6 TROUBLESHOOTING 15 Part Number 72007507B doc Pag...

Page 7: ...riday 6 00 AM to 6 00 PM Mountain Time 1 2 Icons and Conventions This manual uses the following icons and conventions Caution Follow these instructions carefully to avoid danger Note these instructions carefully NORM This typeface indicates a key label or button on the MCU or OAI Gateway 1 3 Installation Overview Installation has three phases In some cases a separate person is responsible for each...

Page 8: ...arty applications to communicate directly with the Link 150 MCU allowing users to retrieve and respond to information using Wireless Telephones A single OAI Gateway is connected to a Link 150 MCU using an Inter Processor Communication IPC cable 8 conductor cable with RJ 45 connectors 2 1 System Diagram Master Control Unit Link Wireless Telephones Base Stations Analog or Digital Interface PBX Appli...

Page 9: ...ators ERROR indicates an internal error Status LEDS LED 1 future use LED 2 future use LED 3 IPC indicates the status of the communication between the OAI Gateway and the other MCUs LED 4 RD indicates the OAI Gateway is receiving data on the RS 232 port LED 5 SD indicates the OAI Gateway is sending data on the RS 232 port PWR indicates status of DC power connection Part Number 72007507B doc Page 9 ...

Page 10: ...sing a 1 8 drill bit drill four pilot holes on 2 inch by 12 1 inch centers 2 In each pilot hole sandwich a star washer between the ESD bonding strap and the backboard then insert the screw 8 panhead wood screw 3 4 inch long and tighten it leaving approximately 1 8 to inch gap from the wall 3 Slide the OAI Gateway over the screw until it drops in place 4 Tighten screws fully 3 2 Conduct Power on Te...

Page 11: ...IPC IN IPC OUT 5 PWR S T A T U S IPC IN RS 232 5 PWR CONN B CONN A OAI Gateway 2 Double check that the IN and OUT ports are correctly connected on all MCUs The first MCU will have no connection to the IN port the last MCU is connected to the OAI Gateway The following diagram shows a chain of four MCUs and the OAI Gateway Do NOT stack the MCUs and OAI Gateway on top of each other Units should be pl...

Page 12: ... OAI Gateway to the PC application server or modem that will be used to interface with the application The OAI Gateway uses the following pins on the connector Pin Function 2 Data OAI Receives 3 Data OAI Transmits 5 Ground If the application is up and running the RD and SD LEDs on the front panel of the OAI Gateway should be lit or blinking indicating that the OAI Gateway is sending and receiving ...

Page 13: ...ng and within range of a Base Station move the Mode switch on the MCU to the ADMIN position 3 Press START on the Wireless Telephone registered to line 2 You should hear a steady tone 4 Press the FCN key followed by the key you want to assign for OAI access 5 Press 555 then press END This assigns OAI to the specified key 6 Return the MCU Mode switch to the NORM position The OAI macro can be program...

Page 14: ...w installation continue with Wireless Telephone registration and PBX programming and perform the usual voice and coverage tests when Wireless Telephone installation is complete If you added the OAI Gateway to an existing system place a call and test the features on each Wireless Telephone to be sure the system is working properly Test the application on each Wireless Telephone The SD and RD LEDs s...

Page 15: ...Flash Stuck in Erase Mode Flash Stuck in Program Mode Flash Fails to CRC Config Readback Fails FPGA Download Fails For any of these errors reset and try again If the error occurs repeatedly contact SpectraLink support RMA may be necessary 4 3 2 1 Queue Overflow Software error Never got config version Reset and try again If the error occurs repeatedly contact SpectraLink support RMA may be necessar...

Reviews: