background image

W-MBus GPRS

AMR Gateway

User Guide version V2.5.1

Gateway software version V3.0.0

ADEUNIS RF

283 rue Louis Néel - Parc Technologique Pré Roux 

38920 CROLLES - France

Tel. : +33 (0)4 76 92 07 77  - Fax : +33 (0)4 76 04 80 87 

www.adeunis-rf.com 

     [email protected]

Summary of Contents for AMR Gateway

Page 1: ...ay User Guide version V2 5 1 Gateway software version V3 0 0 ADEUNIS RF 283 rue Louis Néel Parc Technologique Pré Roux 38920 CROLLES France Tel 33 0 4 76 92 07 77 Fax 33 0 4 76 04 80 87 www adeunis rf com arf adeunis rf com ...

Page 2: ...ned herein Reproduction use or disclosure to third parties without express permission is strictly prohibited Copyright 2012 Adeunis RF Adeunis RF is a registered trademark in the EU and other countries Technical Support Website Our website contains many useful information modules and stand alone products information user guides configuration software and technical documents which can be accessed 2...

Page 3: ...tion 10 2 4 1 External antenna Self powered version ARF8011BA 10 2 4 2 Protection of External antenna Gateway against overloads 10 2 5 Mechanical installation Optimizing Performance 11 2 5 1 AMR Gateway positioning 11 2 5 2 Positioning of the external antenna 11 3 SIM card and GPRS connection 11 4 FTP Organization 11 5 Gateway configuration 12 5 1 File description 12 5 1 1 Configuration file 12 5 ...

Page 4: ... 6 1 1 Compression 17 6 1 2 Encryption 17 6 1 3 Compression encryption 18 6 2 Decryption file 18 6 2 1 File format 18 6 2 2 Hexadecimal format 18 6 2 3 First part 18 6 2 4 Second part 18 6 2 5 Third part 18 6 2 6 Last part 19 6 3 Next frame 19 6 4 Gateway informations 19 7 Document history 19 ...

Page 5: ...8011BDx ARF8011BEx Object of the declaration The object of the declaration described above is in conformity with the relevant Union harmonisation legislation Directive 2014 53 UE RED Directive 2011 65 UE ROHS The following harmonised standards and technical specifications have been applied Title Date of standard specification EN 300 220 2 V3 1 1 2017 02 EN 301 489 1 V2 1 1 2016 11 EN 301 489 3 V2 ...

Page 6: ...8011BDx ARF8011BEx Objet de la déclaration L objet de la déclaration décrit ci dessus est conforme à la législation d harmonisation de l Union applicable Directive 2014 53 UE RED Directive 2011 65 UE ROHS Les normes harmonisées et les spécifications techniques suivantes ont été appliquées Titre Date du standard spécification EN 300 220 2 V3 1 1 2017 02 EN 301 489 1 V2 1 1 2016 11 EN 301 489 3 V2 1...

Page 7: ... close to the equipment Dangerous voltages are present in the product other than mains Before any work they must also be cut All electrical connections to the product must be equipped with a protective device against overload and short circuits 1 3 Usage Recommandations Before using the system check that the supply voltage specified in its user manual corresponds to your power source If this is no...

Page 8: ...to collect frames from radio transmitters meters sensors heat cost allocators using the Wireless M Bus protocol EN13757 and send them as files to a remote FTP server via a GPRS network Markets covered by the AMR Gateway are the metering automatic meter reading and energy efficiency in the building BMS BAS 2 1 Operating principle 2 2 Gateway cycle operation ...

Page 9: ...owered Autonomy 11 years typical General information Storage Operating temperatures 40 85 C 10 60 C Casing and protection IP67 IK8 standards Dimensions 138 x 80 x 58 5mm Weights 485gr Standards EN300 220 EN301 489 EN60950 EN13757 4 2 3 1 Default configuration By default irrespective of the version the configuration of the AMR Gateway is the following WMBUS listening period WMBUS mode GPRS connecti...

Page 10: ...o 4mn 24h 24h 10 7 20ko Binary 20ko 4mn 24h 24h 8 20ko Compressed 12ko 4mn 24h 24h 9 2 20ko Binary 20ko 2mn 24h 24h 8 9 20ko Compressed 12ko 2mn 24h 24h 10 4 20ko Compressed 12ko 2mn 24h 7j 11 20ko Compressed 12ko 2mn 7j 7j 15 2 3 4 Frame length storage ratio The AMR Gateway embeds a microcontroller EEprom capable of storing data from transmitters up to 50Kbytes until the next GPRS transmission De...

Page 11: ...ry to protect the product against lightning When the product is positioned high up it can potentially be struck by lightning which results in irreversible damage to the product All lightning arrester systems can be installed between the aerial and the AMR Gateway It is important to follow the manufacturer s recommendations The diagram below shows an example of a lightning arrester installation N D...

Page 12: ... within a range of less than one metre If the AMR Gateway is installed in a building the aerial should be installed outside The co axial cable should be as short as possible memo cable of 25m 6db of attenuation range divided by 2 3 SIM card and GPRS connection Adeunis RF AMR Gateway includes support for SIM card not accessible to the user Indeed the IP67 and therefore sealing the gateway can only ...

Page 13: ...he following information shows an example of a configuration XML file The colored zones can be modified by user xml version 1 0 encoding UTF 8 config syst version 1 syst enable_serialize no retry_timeout 4 fragment 4000 auto_connection no quad_band yes syst address 193 28 233 151 knet_port 22020 address_bck 193 28 233 239 knet_port_bck 22016 syst apn internet68 apn_bck internet68 syst gprs_tmo 180...

Page 14: ...um number of meter to collect per receive period Reject Meter Already Memorized wmb multi_frame 0 unactivate 1 activate 0 Mutliframe function to receive different frames form a single meter Manufacturer ID Filtering manuf id id See note 1 Note 1 Manufacturer ID Filtering Add an option to choose with MANUF ID defined in 3 letters ARF or in hexacode 4606 MAN ID ASCII 1st letter 64 32 32 ARF 65 64 32...

Page 15: ... 1 Active AES Key cust aes_key 32 bytes 010203 AES Key to use Wake up parameters Description Parameter Format Default Comment Wake Up Day cal dd 8 bytes 7fffffff 1 1 bytes per day Wake Up Hour cal hh 0 to 23 1 Hour number Wake Up GPRS cal tx 0 1 0 No 1 Yes cal the calendar of wake up transmission the list of rules is limited to 24 The fields are dd hexadecimal mask hexadecimal using 32 bits maximu...

Page 16: ...ate 2 Normal mode No specific parameters Installation state 2 parameters inst_d inst_p Time period min 1 max 65535 in minute If value 0 Installation mode inactivated Min 1 max 1440 in minute Description Parameter Format Scan period syst inst_d Num 1 65535 Period between scan syst indt_p Num 1 1440 Running mode syst state 1 or 2 See note 1 5 1 2 Upgrade File 5 1 2 1 File name Type Format SerialPart...

Page 17: ...Contents The following information shows an example of a configuration XML file The colored zones can be modified by user prov clearmeter 5 1 3 3 Parameters Description Parameter Format Default Command prov clearmeter None 5 1 4 Meter File The meter file is used to send to the gateway a list a meter the user want to filter The file will be remove from the FTP server since it take in charge by the ...

Page 18: ...0 Config version 1 Num 1 6 File data 6 1 Extension 6 1 1 Compression The compression function can be activated or deactivated from the configuration file The compression method used is Gzip format For RAM limitation reason the file are cut in 20 kbyte part before compression Each file has the complete format described in previous paragraph and can be processed independently The compressed files us...

Page 19: ... 6 2 2 Hexadecimal format Example 22 13 11 07 15 42 56 b5 19 44 30 4c 07 00 00 00 00 00 a1 61 3f 03 13 97 87 73 98 4f 04 03 41 9f e9 86 22 13 11 07 15 42 56 6c 19 6 2 3 First part Start byte and frame date time Start byte frame length 0x22 Date and time Then from the second to the seventh byte year month day hour min sec YEAR MONTH DAY HOUR MIN SEC Example 13 11 07 15 42 56 for a frame received No...

Page 20: ...y from manufacturing 4 bytes Cumulative working time in seconds 4 bytes Reserved 2 bytes Mobile Country code 2 bytes Mobile Network code 2 bytes Number of valid frames received 2 bytes Number of meters reported in the database held during the last reading 2 bytes Number of meters attached to the gateway 2 bytes Number of meters detected with the expected manufacturer s ID s 2 bytes Number of frame...

Reviews: