3. Technical data
Device model
GEOSTAR G5 LQS
GEOSTAR G5
GEOSTAR G7 LQS
GEOSTAR G7
* Voltage
V~
220 – 240
220 – 240
Power W
2800
2800
Frequency Hz
50 / 60
50 / 60
Temperature, stepless
°C
°F
80 – 460
176 – 788
80 – 460
176 – 788
Drive slow, stepless
m/min
ft./min
0.8 – 6
2.6 – 19.6
0.8 – 7
2.6 – 22.9
Drive fast, stepless
m/min
ft./min
1.5 – 12
4.9 – 39.3
1.5 – 12
4.9 – 39.3
Welding pressure max.
N/lbs
1500 / 337
1500 / 337
Emission level
L
pA
(dB)
60
60
Dimensions (L × W × H)
mm
482 × 278 × 269
482 × 278 × 269
Weight (without power cord) kg/lbs
16.4 / 36.2
17.7 / 39
Mark of conformity
Protection class I
Device
G5
G7
Welding wedge length
mm
90
130
Width of welding wedge
mm
50
50
Weld seam width
mm
2 × 15
We reserve the right to make technical changes. Additional versions upon request
*Connection voltage cannot be switched
Suitable transport equipment
must be
used to transport the machine.
The
welding wedge (5)
must
be cooled down for transport.
Do not store any flammable
materials in the transport box
4. Transport
Do not
use handles on the device or
carrying handles on the transport box for
transport with the crane.
Comply with applicable national regulations regarding the carrying or lifting of loads.