17
14
15
17
16
10
7
8
4
5
11
2
4
10
3
7
8
11
C.
Insert test strips (lower and upper membranes) of the material to be welded between the
upper and lower drive/
pressure rollers (16/17)
and between the
upper and lower contacting systems (14/15)
and
welding wedge (5)
.
Press the
locking clamping lever (10)
and close the
clamping arm (4)
using the
clamping lever (7)
.
Use your other hand to accomplish this by holding the automatic welder firmly by the
handle
(11)
. Rotate the
welding force adjustment ring (8)
until the pressure rollers touch lightly against the material to be welded.
D.
Connect the GEOSTAR to the mains and switch on the
main switch (2)
. Press the
locking clamping lever (10)
and swing the
clamping lever (7)
upwards until the
locking clamping lever engages (10)
. Use your other
hand to accomplish this by holding the automatic welder firmly by the
handle (11)
. Rotate the
welding force
adjustment ring (8)
while open until the welding force on the
operating unit (3)
matches the desired value
with the
clamping arm (4)
clamped and the test strip inserted.
CAUTION!
Mechanical damage could occur if the maximum welding force of 1500 N is exceeded.
Do not touch moving parts
There is a risk of inadvertently becoming caught and being pulled in. Do not wear loose articles
of clothing such as scarves or shawls. Tie up long hair or protect it by wearing headgear.