18
14
5
19
15
2
19
20
10
7
11
E.
Switch off the
main switch (2)
and disconnect GEOSTAR from the mains. While clamped, screw the
lower
contacting system (15)
with the
lower contacting system setting screw (19)
in the direction of the
welding
wedge (5)
until the lower test strip is touching the
welding wedge (5)
. Then rotate the
lower contacting
system setting screw (19)
once in the direction of the
welding wedge (5)
so that the
upper contacting
system (14)
is pre-tensioned.
F.
The
lower contacting system setting screw (19)
must be locked with the
lower contacting system locking
screw (20)
.
G.
Press the
locking clamping le-
ver
(10)
and swing the
clamping
lever (7)
upwards until the
locking
clamping lever (10)
engages. Use
your other hand to accomplish this
by holding the automatic welder
firmly by the
handle (11).
Remove
the test strips. The machine is ready
for use.