507276-03
Page 52 of 59
Issue 1621
Blower Data
NOTES:
All air is measured external to unit without filter (filter not furnished - field provided)
Blower Data A95UH1E & 95G1UHE
A95UH1E & 95G1UHE 030* B08
PERFORMANCE (Less Filter)
External
Static
Pressure
in. w.g.
Air Volume / Watts at Various Blower Speeds
High
Medium-High
Medium
Medium-Low
Low
cfm
Watts
cfm
Watts
cfm
Watts
cfm
Watts
cfm
Watts
0.00
1025
122
935
97
855
76
820
76
765
69
0.10
985
129
910
104
820
82
775
72
700
63
0.20
955
139
875
114
770
87
640
62
575
52
0.30
915
145
830
120
730
96
575
67
375
40
0.40
875
155
790
130
680
101
530
74
330
47
0.50
830
161
750
136
635
110
470
79
260
51
0.60
800
172
700
146
580
115
420
82
210
47
0.70
765
181
650
150
550
124
385
90
180
51
0.80
715
187
615
159
500
127
325
94
135
52
Содержание 95G1UHE
Страница 3: ...507276 03 Page 3 of 59 Issue 1621 EXPANDED VIEW Figure 1 ...
Страница 22: ...507276 03 Page 22 of 59 Issue 1621 Figure 25 Figure 26 ...
Страница 28: ...507276 03 Page 28 of 59 Issue 1621 Figure 34 ...
Страница 38: ...507276 03 Page 38 of 59 Issue 1621 Figure 57 Trap Drain Assembly Using 1 2 PVC or 3 4 PVC ...
Страница 40: ...507276 03 Page 40 of 59 Issue 1621 Figure 59 Figure 60 ...
Страница 44: ...507276 03 Page 44 of 59 Issue 1621 TYPICAL WIRING DIAGRAM Figure 65 ...
Страница 57: ...507276 03 Page 57 of 59 Issue 1621 Start Up Performance Check List ...