Table 14
Unit Size
0 - 4500 ft
(0 - 1,371m)
4501 - 7500 ft
(1371 - 2286m)
7501 - 10000 ft
(2286 - 3048m)
030/045
No Change
No Change
11J09
070
No Change
11J12
10U93
090
No Change
11J11
10U93
110
No Change
11J12
10U93
135
No Change
11J11
10U93
A95 and 95G1 Pressure Switch Requirements at Varying Altitudes
Pressure switch is factory set. No adjustment necessary. All models use the
factory-installed pressure switch from 0-4500 feet (0-1371 m).
Burner Orifice Conversion Kits at Varying Altitudes
Unit
Size
0-7,500 ft
(0-2,286m)
7,501 - 10,000 ft
(2,286 - 3,048 m)
Natural
to
LP/Propane
LP/Propane
to
Natural
High Altitude
Natural
Burner Orifice
Kit
High Altitude
LP/Propane
Burner Orifice
Kit
045
11K50+
73W80*
51W01
11K45+
070
090
110
135
030
14U96+
N/A
N/A
N/A
* Conversion requires installation of a gas valve regulator spring which
is provided with the gas conversion kit.
+ LP Kits include low line pressure switch.
Содержание 95G1UHE
Страница 3: ...507276 03 Page 3 of 59 Issue 1621 EXPANDED VIEW Figure 1 ...
Страница 22: ...507276 03 Page 22 of 59 Issue 1621 Figure 25 Figure 26 ...
Страница 28: ...507276 03 Page 28 of 59 Issue 1621 Figure 34 ...
Страница 38: ...507276 03 Page 38 of 59 Issue 1621 Figure 57 Trap Drain Assembly Using 1 2 PVC or 3 4 PVC ...
Страница 40: ...507276 03 Page 40 of 59 Issue 1621 Figure 59 Figure 60 ...
Страница 44: ...507276 03 Page 44 of 59 Issue 1621 TYPICAL WIRING DIAGRAM Figure 65 ...
Страница 57: ...507276 03 Page 57 of 59 Issue 1621 Start Up Performance Check List ...