A95UH1E & 95G1UHE Maximum Allowable Intake or Exhaust Vent Length in Feet
*Size intake and exhaust pipe length separately. Values in table are for intake OR Exhaust, not combined total. Both Intake and Exhaust
must be same pipe size.
Standard Termination at Elevation 0 - 4,500 ft
Number Of
90°
Elbows
Used
2nd Pipe
2-1/2" Pipe
3" Pipe
Modal
Model
Model
030
045
70
90
110
135
030
045
70
90
110
135
030
045
70
90
110
115
1
76
61
39
19
n/a
110
95
63
38
n/a
132
132
113
113
109
2
71
56
34
14
105
90
58
33
127
127
108
108
104
3
66
51
29
9
100
85
53
28
122
122
103
103
99
4
61
46
24
n/a
95
80
48
23
117
117
98
98
94
5
56
41
19
90
75
43
18
112
112
93
93
89
6
51
36
14
85
70
38
13
107
107
88
88
84
7
46
31
9
80
65
33
8
102
102
83
83
79
8
41
26
n/a
75
60
28
n/a
97
97
78
78
74
9
36
21
70
55
23
92
92
73
73
69
10
31
16
65
50
18
87
87
68
68
64
Standard Termination at Elevation 4,500 - 10,000 ft
Number Of
90°
Elbows
Used
2nd Pipe
2-1/2" Pipe
3" Pipe
Model
Model
Model
030
045
70
90
110
135
030
045
70
Om
110
135
030
045
70
90
110
135
1
76
61
39
n/a
n/a
110
95
63
38
n/a
132
132
113
113
109
2
71
56
34
105
90
58
33
127
127
108
108
104
3
66
51
29
100
85
53
28
122
122
103
103
99
4
61
46
24
95
80
48
23
117
117
98
98
94
5
56
41
19
90
75
43
18
112
112
93
93
89
6
51
36
14
85
70
38
13
107
107
88
88
84
7
46
31
9
80
65
33
8
102
102
83
83
79
8
41
26
n/a
75
60
28
n/a
97
97
78
78
74
9
36
21
70
55
23
92
92
73
73
69
10
31
16
65
50
18
87
87
68
68
64
Maximum Allowable Intake or Exhaust Vent Length in Feet
Table 5
Concentric Termination at Elevation 0 - 4,500 ft
Number Of
90° Elbows
Used
2" Pipe
2-1/2" Pipe
3" Pipe
Model
Model
Model
030
045
70
90
110
135
030
045
70
90
110
135
030
045
70
90
110
135
1
68
53
37
17
n/a
100
85
59
34
n/a
116
116
109
109
100
2
63
48
32
12
95
80
54
29
111
111
104
104
95
3
58
43
27
7
90
75
49
24
106
106
99
99
90
4
53
38
22
n/a
85
70
44
19
101
101
94
94
85
5
48
33
17
80
65
39
14
96
96
89
89
80
6
43
28
12
75
60
34
n/a
91
91
84
84
75
7
38
23
7
70
55
29
86
86
79
79
70
8
33
18
n/a
65
50
24
81
81
74
74
65
9
28
13
60
45
19
76
76
69
69
60
10
23
8
55
40
14
71
71
64
64
55
Concentric Termination Elevation 4500 - 10,000 ft
Number Of
90° Elbows
Used
2" Pipe
2-1/2" Pipe
3" Pipe
Model
Model
Model
030
045
70
90
110
135
030
045
70
90
110
135
030
045
70
0
110
135
1
68
53
37
n/a
n/a
100
85
59
34
n/a
116
116
109
109
100
2
63
48
32
95
80
54
29
111
111
104
104
95
3
58
43
27
90
75
49
24
106
106
99
99
90
4
53
38
22
85
70
44
19
101
101
94
94
85
5
48
33
17
80
65
39
14
96
96
89
89
80
6
43
28
12
75
60
34
n/a
91
91
84
84
75
7
38
23
7
70
55
29
86
86
79
79
70
8
33
18
n/a
65
50
24
81
81
74
74
65
9
28
13
60
45
19
76
76
69
69
60
10
23
8
55
40
14
71
71
64
64
55
Содержание 95G1UHE
Страница 3: ...507276 03 Page 3 of 59 Issue 1621 EXPANDED VIEW Figure 1 ...
Страница 22: ...507276 03 Page 22 of 59 Issue 1621 Figure 25 Figure 26 ...
Страница 28: ...507276 03 Page 28 of 59 Issue 1621 Figure 34 ...
Страница 38: ...507276 03 Page 38 of 59 Issue 1621 Figure 57 Trap Drain Assembly Using 1 2 PVC or 3 4 PVC ...
Страница 40: ...507276 03 Page 40 of 59 Issue 1621 Figure 59 Figure 60 ...
Страница 44: ...507276 03 Page 44 of 59 Issue 1621 TYPICAL WIRING DIAGRAM Figure 65 ...
Страница 57: ...507276 03 Page 57 of 59 Issue 1621 Start Up Performance Check List ...