507276-03
Page 2 of 59
Issue 1621
A95UH1E
& 95G1UHE Unit Dimensions - inches (mm)
1
NOTE
- C20 and D20 (5 Ton) size units installed in upflow
applications that require air volumes of 1800 cfm (850 L/s) or
greater must have one of the following:
1. Single side return air with transition, to accommodate
20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable air filter.
(Required to maintain proper air velocity.)
2. Single side return air with optional “RAB”
R
eturn
A
ir
B
ase.
3. Bottom return air.
4. Return air from both sides.
5. Bottom and one side return air.
See “Blower Performance Tables” for additional information.
2
Optional External Side Return Air Filter kit is not for use with
optional Return Air Base.
* Consider sizing requirements for optional IAQ equipment before
cutting side return opening.
FRONT VIEW
SIDE VIEW
Model
A95UH1E & 95G1UHE
A
B
C
D
in.
mm
in.
mm
in.
mm
in.
mm
030-08
045-08
045-12
070-08
070-12
17-1/2
446
16-3/8
416
16
406
7-5/8
194
090-12
090-16
110-12
110-16
110-20
21
533
19-7/8
505
19-1/2
495
9-3/8
238
135-20
24-1/2
622
23-3/8
594
23
584
11-1/8
283
Содержание 95G1UHE
Страница 3: ...507276 03 Page 3 of 59 Issue 1621 EXPANDED VIEW Figure 1 ...
Страница 22: ...507276 03 Page 22 of 59 Issue 1621 Figure 25 Figure 26 ...
Страница 28: ...507276 03 Page 28 of 59 Issue 1621 Figure 34 ...
Страница 38: ...507276 03 Page 38 of 59 Issue 1621 Figure 57 Trap Drain Assembly Using 1 2 PVC or 3 4 PVC ...
Страница 40: ...507276 03 Page 40 of 59 Issue 1621 Figure 59 Figure 60 ...
Страница 44: ...507276 03 Page 44 of 59 Issue 1621 TYPICAL WIRING DIAGRAM Figure 65 ...
Страница 57: ...507276 03 Page 57 of 59 Issue 1621 Start Up Performance Check List ...