Triggering
197
Goldeye G/CL Technical Manual V4.2.0
I/O types
Non-isolated I/Os:
•
One non-isolated line-in (3.3 V LVTTL, 5 V TTL tolerated, see
)
•
One non-isolated line-out (5 V TTL)
•
(Camera Link only) Four non-isolated LVDS inputs (CC ports)
Opto-isolated I/Os:
•
One opto-isolated line-in
•
Two opto-isolated line-out
•
Maximum isolated power voltage is 30 V
•
Line-in voltages:
-
V
in
(low) = 0.0 V to 1.0 V
-
V
in
(high) = 3.0 V to 24.0 V
Quick overview: trigger cables with 12-pin Hirose
connector
Cable side Hirose connectors (without cable) and I/O cables with Hirose connector
are available for purchase from Allied Vision.
If you use other I/O cables, the maximum length of the I/O cable must not exceed
30 meters.
Description
Product code
Trigger cable In1 BNC LVTTL with Hirose 12-pin connector, 2 m
1068908
Trigger cable In1 BNC LVTTL with Hirose 12-pin connector, 5 m
1068909
Table 125: Available trigger cables with Hirose 12-pin connector