Next, check the PAC’s status using the command:
SHOW LOG
to display a log of PAC events. A typical display is shown in
Figure 29
.
Figure 29: Example output from the SHOW LOG command for a Rapier switch with an
AT-AR061 ECPAC card installed
If PAC tests fail, check that the PAC is correctly installed in its slot and repeat
the tests. Contact your authorised Allied Telesis distributor or reseller if the
PAC does not operate correctly.
Once the PAC is operating, its functionality can be tested either by using the
Test Facility software, which is built into the switch, or by configuring a
module to use the PAC. For more information about configuring interfaces, see
the “Compression and Encryption Services” chapter of your switch’s Software
Reference.
Using the Test Facility to Verify Operation
The built-in Test Facility software is the easiest way to verify a PAC’s operation.
For more information, see the
Test Facility
chapter in the Software Reference.
To run the test facility for a PAC, use the command:
ENABLE TEST INTERFACE=PAC
The test runs 4 minutes. To view the results of the test at any time, use the
command:
SHOW TEST
Date/Time S Mod Type SType Message
--------------------------------------------------------------------------
15 00:05:50 4 ENCO ENCO PAC 7751 Found. Initialisation started
15 00:05:50 4 ENCO ENCO PAC 7751 Initialisation Successful
15 00:05:50 7 SYS REST NORM Switch startup, ver 2.2.2-00, 18-May-2001,
Clock
Log: 00:04:40 on 15-Jun-2001
15 00:05:53 3 USER USER 00011 manager login failed on port0
15 00:05:58 3 USER USER LON manager login on port0
15 00:05:59 3 CH MSG WARN No patches found
--------------------------------------------------------------------------