20
Rapier Series Switch
C613-03020-00 REV K
INFO: Self tests complete.
The start-up tests have finished.
INFO: Downloading switch software.
The process of downloading the switch software and vector table from
ROM is about to begin.
ERROR: Code load retried.
FAIL: Code load failed.
The load of the code from ROM to RAM failed. The load is retried a
number of times. Each time a failure occurs, the ERROR message is
displayed. If the maximum number of attempts is reached, the FAIL
message is displayed.
INFO: Initial download succeeded.
The start-up tests and download are complete, and the switch software
is about to be started. If the default install is a compressed release, the
release will now be decompressed. This may take a few seconds.
INFO: Downloading compressed release. This may take up to 1
minute...
INFO: Loading software into memory. This may take up to 1
minute...
The main switch software is about to be loaded into RAM. If the version
is a compressed release, the release will be decompressed.
INFO: Executing configuration script <script-name>
The configuration commands stored in <script-name> are being
executed. If an error is found in the script, one or more ERROR
messages will be displayed.
INFO: Switch startup complete.
The start-up process is complete and the switch will now perform basic
switching operations. Further configuration will be necessary if you wish to
access the switch’s full layer 3 switching capabilities. See the
Rapier Series
Switch AlliedWare™ Operating System Software Reference
for detailed information
on configuring the switch.