114
802748
Dryer Test Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect all electric power to the machine and accessories before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start machine with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
• Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
66. Door Switch
a. While supporting the access panel, remove
two screws from bottom edge of access panel.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel.
c. Remove two screws holding bottom tabs on
front panel to dryer side panels. Swing bottom
of front panel away from dryer far enough to
disengage hold-down clips and locators from
cabinet top.
d. Disconnect wires from door switch.
NOTE: Refer to model wiring diagram when
rewiring door switch.
e. Set meter to read Ohms and apply meter
probes on switch terminals 1 and 3 with door
closed. You should get “zero” reading.
f. Apply probes to terminals 1 and 2 with door
closed. The meter should read “infinite”.
g. Open door. Meter should read “infinite”
between 1 and 3 and “zero” between 1 and 2.