802748
Adjustments
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect all electric power to the machine and accessories before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start machine with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
• Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
53. Burner Flame (Gas Models)
a. While supporting the access panel, remove
two screws from bottom edge of access panel.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel.
c. Add coins or card to satisfy vend.
d. Close the loading door. Start the dryer in a
heat setting (refer to Operating Instructions
supplied with the dryer). The dryer will start,
the igniter will glow red, and the main burner
will ignite.
e. Allow the dryer to operate for approximately
five minutes, then loosen the air shutter
lockscrew. Refer to
Figure 19
.
f. Turn the air shutter to the left to get a
luminous yellow-tipped flame, then turn it
back slowly to the right to obtain a steady blue
flame.
g. After proper flame is obtained, tighten air
shutter lockscrew firmly. Refer to
Figure 19
.
h. Reinstall access panel and screws.
NOTE: After the dryer has operated for
approximately three minutes, exhaust air or
exhaust pipe should be warm.
To reduce the risk of fire or serious injury,
the access panel must be in place during
normal operation.
W262
WARNING
Figure 19
Air
S
hutter
Lock
s
crew
Air
S
hutter
S
hut-Off Valve
Handle
1/
8
Inch Pipe Plu
g
(For checkin
g
manifold pre
ss
ure)
D265