Dryer Test Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect all electric power to the machine and accessories before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start machine with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
• Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
63. Thermal Fuse (Electric Models)
a. While supporting the access panel, remove
two screws from bottom edge of front access
panel.
b. Gently lower the access panel to disengage
panel locators from bottom edge of front
panel.
c. Label and disconnect wires from thermal
fuse.
NOTE: Refer to wiring diagram when rewiring
thermal fuse.
d. Set multimeter to read Ohms. Apply meter
probes to thermal fuse terminals. Multimeter
should read 0 Ohms. If the meter does not
show any reading (infinite Ohms), then the
fuse is open. If the fuse is open, then replace
BOTH the thermal fuse and the limit
thermostat.
64. Heater Assembly (Electric
Models)
a. While supporting the access panel, remove
two screws from bottom edge of access panel.
b. Gently lower the access panel to disengage
panel locators from bottom edge of front
panel.
c. Disconnect wires from heater assembly.
NOTE: Refer to wiring diagram when rewiring
heater assembly.
d. Set meter to read Ohms. Apply meter probes
to the heater assembly terminals. Meter
should read as follows: (Cold Ohms).
65. Cycling or Limit Thermostat
a. While supporting the access panel, remove
two screws from bottom edge of access panel.
b. Gently lower the access panel to disengage
panel locators from bottom edge of front
panel.
c. Label and disconnect wires from thermostat.
NOTE: Refer to wiring diagram when rewiring
thermostat.
Cycling Thermostat (S.P.S.T. – 2 Terminals)
or Limit Thermostat
d. Set meter to read Ohms.
(1)Apply meter probes to the thermostat
terminals.
(2)Meter should read “zero.”
Element
Color
Code
KW Voltage/Hz.
Resistance Reading
Red
5
240 V 60 Hz. 10.39 ± .31 Ohms Cold
White
4.75 208 V 60 Hz. 8.2 ± .5 Ohms Cold
Green
4.8
240 V 50 Hz. 10.75 ± .32 Ohms Cold
Yellow
4
240 V 50 Hz. 13.03 ± .39 Ohms Cold
Blue
3.1
240 V 50 Hz. 16.7 ± .5 Ohms Cold
Orange
5.35 240 V 60 Hz. 9.72 ± .3 Ohms Cold
Purple
4.25 208 V 60 Hz. 9.27 ± .3 Ohms Cold