66
802748
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NetMaster Troubleshooting – Dryer Control
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect all electric power to the machine and accessories before servicing.
• Close gas shut-off valve to gas dryer before servicing.
• Never start machine with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the machine is properly grounded.
• Washer motor not grounded! Disconnect electric power before servicing motor.
W502
WARNING
Right most
DP (decimal
point) Lit
Network Communication Error
Communication problem. Wait for 1.5 minutes for error to
clear. If it doesn’t, power-down and power-up the machine. If
error persists, control or Network Board may need to be
replaced.
Err
Coin Error
Invalid coin pulse.
Alrm
Breakin Alarm Error
Service door or coin vault switches.
OFF
Breakin Alarm Shutdown Error
Service door or coin vault switches.
E:OP
Open Thermistor Error
Physical “open” in thermistor circuit. Possible causes are
thermistor, wiring between control and thermistor, or control.
E:SH
Shorted Thermistor Error
“Short” in thermistor circuit. Possible causes are shorted
thermistor, short in wiring between control and thermistor, or
control.
E:00
General Error
Re-aim Micro-wand and try again.
E:01
Proximity Error
Micro-wand is improperly aimed at infrared communicator
(angle or distance). Re-aim Micro-wand and try again.
E:02
IR Communication Disconnection
Micro-wand removed before communication complete. Re-aim
micro-wand and try again.
E:05
Invalid Value Communication
Invalid code downloaded from Micro-wand to Electronic
Control. Before downloading, ensure data is for current
machine type.
E:07
Inoperative Control
Replace control.
E:08
Inoperative Control
Replace control.
E:09
Proximity Error
Micro-wand is improperly aimed at infrared communicator
(angle or distance). Re-aim Micro-wand and try again.
EI:0A
Proximity Error
Micro-wand is improperly aimed at infrared communicator
(angle or distance). Re-aim Micro-wand and try again.
E:0B
IR Communication Disconnection
Micro-wand removed before communication complete. Re-aim
Micro-wand and try again.
E:0C
IR Communication Disconnection
Micro-wand removed before communication complete. Re-aim
Micro-wand and try again.
E:0F
IR Communicator Programmed Off Reprogram infrared communicator on. Manually enable IR on
control/Re-aim micro-wand and try again.
Err
Coin Error
Inoperative coin sensor. Check coin drop area and remove
obstructions. Possible tampering. Evaluate security procedures.
Display
Description
Cause/ Corrective Action
Содержание BTEBCFSP171TW01 BTEBEFSP171TW01
Страница 2: ......
Страница 106: ...104 802748 Adjustments Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...