W502
WARNING
EC:19
No Card Reader Communication
Communication problem. Power down, power up and try
again. If error persists, control or reader is bad.
EC:20
Unreadable Card
Bad card/ dirty contact. Clean chip on card or card reader
contacts. Try card again. If error persists, card may be bad.
EC:21
Security ID Mismatch
Wrong card. Use card with correct security code.
EC:22
Site Code Mismatch
Wrong card. Use card with correct site code.
EC:23
Card Maximum Value Exceeded
Value on card over max. Use a card which does not exceed
maximum value.
EC:24
Insufficient Memory on Card
Card memory is full. Download card contents to PC and clear
card for re-use.
EC:25
Card Reader Malfunction
Bad Card Reader. Card Reader may need to be replaced.
EC:26
Card Write Error
Try card again. If error persists, card may be bad.
EC:27
Diagnostic Test Card Write Failure Bad Card Reader. Card Reader may need to be replaced.
EC:28
Diagnostic Test Card Read Failure
Bad Card Reader. Card Reader may need to be replaced.
EC:29
Diagnostic Test Memory Test
Failure
Bad Card Reader. Card Reader may need to be replaced.
EC:2A
Diagnostic Test Card Interface
Failure
Bad Card Reader. Card Reader may need to be replaced.
EC:2b
Diagnostic Test Flash Checksum
Failure
Bad Card Reader. Card Reader may need to be replaced.
EC:2C
Bad Biberon or Non-biberon
Device
Bad Card Reader. Card Reader may need to be replaced.
EC:2d
Firmware Update Failed,
S/W (Software) Intact
Firmware load failed. Card Reader may need to be replaced.
EC:2E
Firmware Update Failed, S/W Not
Intact
Bad firmware in reader. Card Reader may need to be replaced.
EC:2F
Firmware Updated, S/W Not Intact Bad firmware in reader. Card Reader may need to be replaced.
EC:30
Timeout Error
Card Reader may need to be replaced.
EC:31
Hotlisted Card Inserted Into Reader Card hotlisted. Control will destroy card.
EC:50
Loyalty Purse Read Error
Try card again. If error persists, card may be bad.
EC:56
Loyalty Purse Write Error
Try card again. If error persists, card may be bad.
Display
Description