Individual Diagnostic Tests
Test Name
Display
Description
Dryer On Temp Test
"Close Door" and "Waiting"
"Close Lint Door" and "Waiting"
"Cooling" and "Time Remaining" and
"MM:SS"
"Close Door, Ready, Running"; Target
Temperature: XXXF or XXXC; Actual:
XXXF or XXXC
If the door is open, the display will show
Close Door. Once the door is closed,
Start will become active and can be
pressed to start the test. After the test is
started, Start will change to Stop. Press-
ing Stop will stop the test. Opening either
the loading door or lint door will also
stop and exit the test. The test will run
until the target temperature is reached or
99 minutes have expired. Once the heat-
ing portion of the test finishes, the ma-
chine will transition to cool down and
will run cool down for one (1) minute.
12.5VDC Voltage Test
XX.XXV
XXX.XX is the value of the 12.5VDC
supply. “V” is volts.
24VDC Voltage Test
"Close Door" and "Waiting"
"Close Lint Door" and "Waiting"
XX.XXV
XXX.XX is the value of the 24VDC sup-
ply. “V” is volts.
AC Mains Voltage Test
XXX
XXX is the current AC Mains Voltage.
ICM Alarm Status (gas models)
"Locked", "Ready" or "Resetting"
When the ICM alarm status test is select-
ed, the control will display the appropriate
status of the ICM alarm signal. If the ICM
alarm is active for at least one second, the
control will show "Locked". If the ICM
alarm is not active for one second, the con-
trol will show "Ready". If the status is
locked, the reset button will be active and
if the reset button is pressed, the control
will show "Resetting" and the button will
become inactive again.
Table 7
continues...
Diagnostics Menu
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
55
Part No. 70600001ENR6