Factory Tests
Test Name
Display
Description
10 Minute Test Cycle
"Temp Setpoint", "Time: M:SS", "Temper-
ature: XXXY"
Determines if tumble dryer can function in
a cycle for 10 minutes. The control will
prompt the user to press Start to run the
cycle. While this 10 Minute Test Cycle is
running, the Start button may be used to
decrement the remaining cycle time. If
power to the control is turned off before
this test cycle has ended, the cycle is
cleared. When the control is powered back
up, it will be reset to Ready Mode. Display
shows "Temperature: XXXY", where XX
is the temperature and Y is the units (Cel-
sius or Fahrenheit). Pressing the "Temp
Select" button will cycle through different
temperature setpoints. Pressing the next
step button will decrement the time by one
minute per press.
Table 6
Individual Tests Menu
TMB1877R_SVG
Figure 48
The Individual Tests Menu allows the user to preform individual
manual diagnostic tests on machine components. Refer to
.
1. To access, touch INDIVIDUAL TESTS from the
.
2. Swipe to scroll through the list of individual tests.
3. Touch the desired individual test.
4. Touch START to begin each individual test.
NOTE: The time remaining in the test step displays
while the step is in process. The control indicates
the test results when the test step is complete.
5. Touch STOP to terminate the individual test.
6. Touch another test step name from the list to navigates be-
tween test steps.
7. When finished running the individual tests, touch INDIVIDU-
Diagnostics Menu
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
54
Part No. 70600001ENR6
Содержание SG025D
Страница 2: ......