switch as open, the air flow switch will be observed as open if the
alarm input detects it open for 0.25 seconds.
Break-In Alarm Error
If enabled in programming, the user has (30) seconds to enter the
bypass passcode after opening the Service Door and/or Coin
Vault. If thirty (30) seconds expire or an incorrect passcode is en-
tered, the control triggers the a Break-In Alarm.
The control signals a network alarm, cause a machine alarm or
shut down the machine. The date and time of the break-in is re-
corded.
The owner can program an alarm to sound (if the passcode is not
correctly entered) upon Coin Vault Opening, Service Door Open-
ing or both.The error is non-fatal will clear by itself after 15 sec-
onds.
The owner can also program the machine to shut down (if the
passcode is not correctly entered) upon Coin Vault Opening,
Service Door Opening or both. The error is fatal and the control
will shut down the machine at the end of a cycle, if one is in
process.
The hour, date and error code of the event are saved in audit. The
error display takes priority over any other error that is already set.
To avoid the alarm during coin collections, the alarm must be
turned off or temporarily disabled
Board ID Error (Fatal)
This error occurs when an incorrect board is connected for the
machine type and configuration.
The control checks that the connected drive or output board is the
correct board. The control also checks that the correct drive and
auxiliary output board is connected. The control sets the Board
ID Error if the wrong drive motor or auxiliary board is connected
for the machine configuration. The display shows Output Board
ID Error, Drive Board ID Error , "Fan Board ID Error" or "ICM
Board ID Error" according to the error.
Brownout/Voltage Configuration Error
This error occurs if the control senses input voltage that does not
match the machine configuration. The display shows "Voltage
Configuration Error". To clear the error, correct the the input volt-
age or the voltage configuration parameter (refer to
), then cycle power to the machine power.
Cabinet Limit Cycle Error
This error is an end of cycle error. While there is a call for heat, if
the cabinet temperature causes the cabinet limit to open, the heat-
er will be turned off and the control will continue the cycle with
no heat until the limit thermostat resets. At the end of the cycle
the control will show the Message Page with "Cabinet Limit Cy-
cle" if the Display Limit Cycles programming parameter is ena-
bled. The control will continue displaying the error message until
the error is cleared. Extended tumble will be allowed while the
error is present after the cycle has completed.
The control will increment the cabinet limit cycle audit counter
only once per cycle.
Coin Drop Error
If enabled in programming, a Coin Drop Error occurs if a coin in-
put pulse is too short, if the input is too long or if the input is too
close to the previous input. The control displays "Coin Error" and
turn on the Machine Error Tone for five (5) seconds, after which
the error terminates. The coin error #1 or #2 audit counters will
be incremented. Any valid coins are accepted normally and will
terminate the error condition.
If the coin error penalty parameter is enabled and the coin error is
enabled in programming, when a coin error occurs all vend prog-
ress is lost and the control returns to the
.
Communication B Errors
Communication B Errors occur when the control cannot properly
communicate with an external device, indicating a problem with
the USB Serial Communication. These errors not displayed, but
are recorded in
codes.
Error Code
Descriptions
3
Invalid Command
4
Unexpected Data
5
Out of Range Data
6
No Data Received
7
Invalid Data Length
8
Invalid Command Length
Table 8
Diagnostics Menu
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
58
Part No. 70600001ENR6