Installation
25
802957
Step 8: Position and Level the Unit
Position unit so it has sufficient clearance for
installation and servicing. Refer to
Figure 23
.
Figure 23
NOTE: Use of the dispenser drawer or unit doors
as a handle in the transportation of the unit may
cause damage to the dispenser or doors.
Place unit in position on a solid, sturdy and level floor.
Installing the unit on any type of carpeting, soft tile, a
platform or other weakly supported structures is not
recommended.
NOTE: Shaded areas indicate adjacent structure.
SWD795N
SWD795N
A
B
C
D
E
E
Dryer and Exhaust Duct Clearances
Area
Description
Minimum Clearance
A
Left Dryer Side
0" (0 cm)
B
Right Dryer Side
1" (2.54 cm)
C
Dryer Top
6" (15.24 cm)
D
Dryer Rear
4" (10.2 cm)
E
Exhaust Duct Clearance to Combustible Materials
2" (5.1 cm)