Parameter Information
Appendix A
201
Transient Zero
0/10
5.00
Provides the ability to adjust the gain factor used in speed
measurement algorithms. These parameters are not typically
modified and it is recommended that RA Technical Support be
contacted for assistance before attempting to do so.
R/W
202
Transient Gain
0/4
1.00
Provides the ability to adjust the gain factor used in speed
measurement algorithms. These parameters are not typically
modified and it is recommended that RA Technical Support be
contacted for assistance before attempting to do so.
R/W
203
Ping Degree
0/180
50.0
Timing parameter used in speed measurement algorithms.
These parameters are not typically modified and it is
recommended that RA Technical Support be contacted for
assistance before attempting to do so.
R/W
204
Pings
0/20
2
Timing parameter used in speed measurement algorithms.
These parameters are not typically modified and it is
recommended that RA Technical Support be contacted for
assistance before attempting to do so.
R/W
205
Phase Shift 0
-360/360
0
Timing parameters used in speed measurement algorithms.
These parameters are not typically modified and it is
recommended that RA Technical Support be contacted for
assistance before attempting to do so.
R/W
206
Phase Shift 10
-360/360
0
Timing parameters used in speed measurement algorithms.
These parameters are not typically modified and it is
recommended that RA Technical Support be contacted for
assistance before attempting to do so.
R/W
207
Phase Shift 20
-360/360
0
Timing parameters used in speed measurement algorithms.
These parameters are not typically modified and it is
recommended that RA Technical Support be contacted for
assistance before attempting to do so.
R/W
208
Phase Shift 30
-360/360
0
Timing parameters used in speed measurement algorithms.
These parameters are not typically modified and it is
recommended that RA Technical Support be contacted for
assistance before attempting to do so.
R/W
209
Phase Shift 40
-360/360
0
Timing parameters used in speed measurement algorithms.
These parameters are not typically modified and it is
recommended that RA Technical Support be contacted for
assistance before attempting to do so.
R/W
210
Phase Shift 50
-360/360
0
Timing parameters used in speed measurement algorithms.
These parameters are not typically modified and it is
recommended that RA Technical Support be contacted for
assistance before attempting to do so.
R/W
211
Phase Shift 60
-360/360
0
Timing parameters used in speed measurement algorithms.
These parameters are not typically modified and it is
recommended that RA Technical Support be contacted for
assistance before attempting to do so.
R/W
212
Phase Shift 70
-360/360
0
Timing parameters used in speed measurement algorithms.
These parameters are not typically modified and it is
recommended that RA Technical Support be contacted for
assistance before attempting to do so.
R/W
213
Phase Shift 80
-360/360
0
Timing parameters used in speed measurement algorithms.
These parameters are not typically modified and it is
recommended that RA Technical Support be contacted for
assistance before attempting to do so.
R/W
214
Phase Shift 90
-360/360
0
Timing parameters used in speed measurement algorithms.
These parameters are not typically modified and it is
recommended that RA Technical Support be contacted for
assistance before attempting to do so.
R/W
Table 66 - SMC -50 Parameter List (Continued)
Number
Name
Unit
Min/Max
Default
Enum Text
Description
R/W
Содержание SMC-50
Страница 10: ...10 Rockwell Automation Publication 1560F UM001A EN P June 2019 Table of Contents Notes ...
Страница 12: ...12 Rockwell Automation Publication 1560F UM001A EN P June 2019 Preface Notes ...
Страница 68: ...68 Rockwell Automation Publication 1560F UM001A EN P June 2019 Chapter 2 Installation Notes ...
Страница 120: ...120 Rockwell Automation Publication 1560F UM001A EN P June 2019 Chapter 4 Programming Notes ...
Страница 130: ...130 Rockwell Automation Publication 1560F UM001A EN P June 2019 Chapter 5 Metering Notes ...
Страница 134: ...134 Rockwell Automation Publication 1560F UM001A EN P June 2019 Chapter 6 Optional HIM Operation Notes ...
Страница 144: ...144 Rockwell Automation Publication 1560F UM001A EN P June 2019 Chapter 7 Communications Notes ...
Страница 156: ...156 Rockwell Automation Publication 1560F UM001A EN P June 2019 Chapter 8 Diagnostics Notes ...
Страница 198: ...198 Rockwell Automation Publication 1560F UM001A EN P June 2019 Chapter 10 Maintenance Notes ...
Страница 240: ...240 Rockwell Automation Publication 1560F UM001A EN P June 2019 Appendix A Parameter Information Notes ...
Страница 242: ...242 Rockwell Automation Publication 1560F UM001A EN P June 2019 Appendix B Controller Duty Cycle Ratings Notes ...
Страница 250: ...250 Rockwell Automation Publication 1560F UM001A EN P June 2019 Appendix C 1560F and 1562F Relay Control Notes ...
Страница 280: ...280 Rockwell Automation Publication 1560F UM001A EN P June 2019 Appendix G Using DeviceLogix Notes ...
Страница 284: ...284 Rockwell Automation Publication 1560F UM001A EN P June 2019 Appendix H Spare Parts Notes ...
Страница 286: ...286 Rockwell Automation Publication 1560F UM001A EN P June 2019 Appendix I Accessories Notes ...
Страница 291: ......